Dielectric Double Jacket (PDP) (EDHNA2J) Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* General Cable** Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 to 60 6 EDHNA2J-12-AA-006-BB XX0064H1A-DT 5 0.46 11.7 63 96 9 23 5 12 41,010 12,500 12 EDHNA2J-12-AA-012-BB XX0124H1A-DT 24 EDHNA2J-12-AA-024-BB XX0244H1A-DT 36 EDHNA2J-12-AA-036-BB XX0364H1A-DT 48 EDHNA2J-12-AA-048-BB XX0484H1A-DT 72 72 EDHNA2J-12-AA-072-BB XX0724H1A-DT 6 0.48 12.2 73 108 10 25 5 12 41,010 12,500 84 to 96 96 EDHNA2J-12-AA-096-BB XX0964H1A-DT 8 0.54 13.8 89 133 11 28 5 14 41,010 12,500 108 to 120 120 EDHNA2J-12-AA-120-BB XX1204H1A-DT 10 0.61 15.4 111 165 12 31 6 15 41,010 12,500 132 to 144 144 EDHNA2J-12-AA-144-BB XX1444H1A-DT 12 0.67 17.1 133 198 13 34 7 17 41,010 12,500 156 to 216 216 EDHNA2J-12-AA-216-BB XX2164H1A-DT 18 0.67 17.1 137 204 13 34 7 17 41,010 12,500 228 to 264 264 EDHNA2J-12-AA-264-BB XX2644H1A-DT 22 0.74 18.7 159 237 15 37 7 19 36,138 11,016 276 to 288 288 EDHNA2J-12-AA-288-BB XX2884H1A-DT 24 0.78 19.8 179 266 16 40 8 20 33,220 10,126 Double Jacket Double Armored (SPSP) (EDH2A2J) Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* General Cable** Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 to 60 6 EDH2A2J-12-AA-006-BB XX0064H1S-DT 5 0.64 16.3 182 272 13 33 6 16 41,010 12,500 12 EDH2A2J-12-AA-012-BB XX0124H1S-DT 24 EDH2A2J-12-AA-024-BB XX0244H1S-DT 36 EDH2A2J-12-AA-036-BB XX0364H1S-DT 48 EDH2A2J-12-AA-048-BB XX0484H1S-DT 72 72 EDH2A2J-12-AA-072-BB XX0724H1S-DT 6 0.67 17.1 194 289 13 34 7 17 41,010 12,500 84 to 96 96 EDH2A2J-12-AA-096-BB XX0964H1S-DT 8 0.75 19.1 226 336 15 38 8 19 35,306 10,762 108 to 120 120 EDH2A2J-12-AA-120-BB XX1204H1S-DT 10 0.80 20.4 258 384 16 41 8 20 31,096 9,479 132 to 144 144 EDH2A2J-12-AA-144-BB XX1444H1S-DT 12 0.88 22.4 312 465 18 45 9 22 25,630 7,813 156 to 216 216 EDH2A2J-12-AA-216-BB XX2164H1S-DT 18 0.88 22.4 305 454 18 45 9 22 25,630 7,813 228 to 264 264 EDH2A2J-12-AA-264-BB XX2644H1S-DT 22 0.94 23.9 338 503 19 48 9 24 22,400 6,828 276 to 288 288 EDH2A2J-12-AA-288-BB XX2884H1S-DT 24 0.98 24.9 368 547 20 50 10 25 20,282 6,182 Triple Jacket Double Armored (PSPSP) (EDH2A3J) Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* General Cable** Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 to 60 6 EDH2A3J-12-AA-006-BB XX0064E1S-DT 5 0.70 17.8 215 320 14 36 7 18 40,248 12,268 12 EDH2A3J-12-AA-012-BB XX0124E1S-DT 24 EDH2A3J-12-AA-024-BB XX0244E1S-DT 36 EDH2A3J-12-AA-036-BB XX0364E1S-DT 48 EDH2A3J-12-AA-048-BB XX0484E1S-DT 72 72 EDH2A3J-12-AA-072-BB XX0724E1S-DT 6 0.73 18.6 228 339 15 37 7 19 35,654 10,868 84 to 96 96 EDH2A3J-12-AA-096-BB XX0964E1S-DT 8 0.78 19.9 265 394 16 40 8 20 31,852 9,709 108 to 120 120 EDH2A3J-12-AA-120-BB XX1204E1S-DT 10 0.86 21.9 313 466 17 43 9 22 27,160 8,279 132 to 144 144 EDH2A3J-12-AA-144-BB XX1444E1S-DT 12 0.93 23.7 367 546 19 47 9 24 22,330 6,807 156 to 216 216 EDH2A3J-12-AA-216-BB XX2164E1S-DT 18 0.93 23.7 367 546 19 47 9 24 22,330 6,807 228 to 264 264 EDH2A3J-12-AA-264-BB XX2644E1S-DT 22 0.98 25.0 402 598 20 50 10 25 20,312 6,192 276 to 288 288 EDH2A3J-12-AA-288-BB XX2884E1S-DT 24 1.02 26.0 429 639 20 52 10 26 18,680 5,694 Temperature Range Shipping and Storage: -40° F to +167° F (-40° C to +75° C) Installation: -22° F to +140° F (-30° C to +60° C) Operation: -40° F to +158° F (-40° C to +70° C) Installation Maximum installation load: 600 lbf (2700 N) Maximum operation load: 180 lbf (800 N) Mechanical Performance (per ICEA 640 and Telcordia GR20) Minimum installation bend radius: 20 times the cable diameter Minimum operating bend radius: 10 times the cable diameter Short Term Compression: 220 N/cm over 10 cm (125 lb/in over 4 inches) Long Term Compression: 110 N/cm over 10 cm (62.5 lb/in over 4 inches) Impact Load: 4.4 Nm * Where AA equals glass type and BB equals attenuation ** Where XX equals glass type ExpressLT™ Dry Dry Loose Tube Cable (2.5mm) Prysmian 4 Tesseneer Drive, Highland Heights, KY 41076 na.prysmian.com TLS-DS-A-101-0825 OUTDOOR CABLES 165
Powered by Prysmian North America
Datacom Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait