CampusLink LT™ Riser I/O Dielectric Single Jacket (1J - GEL), DRLTB Series | OFNR/FT4 Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 - 48 6 DRLTB-12-AA-006-BB 5 0.40 10.1 67 99 8 20 4 10 41,010 12,500 12 DRLTB-12-AA-012-BB 24 DRLTB-12-AA-024-BB 36 DRLTB-12-AA-036-BB 48 DRLTB-12-AA-048-BB 72 72 DRLTB-12-AA-072-BB 6 0.43 10.8 74 110 9 22 4 11 41,010 12,500 96 96 DRLTB-12-AA-096-BB 8 0.50 12.8 103 153 10 26 5 13 41,010 12,500 120 120 DRLTB-12-AA-120-BB 10 0.57 14.5 132 196 11 29 6 15 41,010 12,500 144 144 DRLTB-12-AA-144-BB 12 0.64 16.3 168 250 13 33 6 16 41,010 12,500 CampusLink LT™ Riser I/O Dielectric Double Jacket (2J - GEL), DRLTC Series | OFNR/FT4 Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 - 48 6 DRLTC-12-AA-006-BB 5 0.52 13.2 118 176 10 26 5 13 41,010 12,500 12 DRLTC-12-AA-012-BB 24 DRLTC-12-AA-024-BB 36 DRLTC-12-AA-036-BB 48 DRLTC-12-AA-048-BB 72 72 DRLTC-12-AA-072-BB 6 0.55 13.9 128 191 11 28 5 14 41,010 12,500 96 96 DRLTC-12-AA-096-BB 8 0.63 15.9 166 247 13 32 6 16 41,010 12,500 120 120 DRLTC-12-AA-120-BB 10 0.69 17.6 202 301 14 35 7 18 33,524 10,218 144 144 DRLTC-12-AA-144-BB 12 0.76 19.4 247 367 15 39 8 19 33,524 10,218 CampusLink LT™ I/O Riser Corrugated Steel Tape Armor with Double Jackets (1A2J - GEL) DRLTD series | OFCR / FT4 Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 - 48 6 DRLTD-12-AA-006-BB 5 0.63 16.0 194 289 13 32 6 16 41,010 12,500 12 DRLTD-12-AA-012-BB 24 DRLTD-12-AA-024-BB 36 DRLTD-12-AA-036-BB 48 DRLTD-12-AA-048-BB 72 72 DRLTD-12-AA-072-BB 6 0.66 16.8 209 311 13 34 7 17 41,010 12,500 96 96 DRLTD-12-AA-096-BB 8 0.74 18.8 257 383 15 38 7 19 35,656 10,868 120 120 DRLTD-12-AA-120-BB 10 0.80 20.3 303 451 16 41 8 20 25,633 7,813 144 144 DRLTD-12-AA-144-BB 12 0.88 22.4 358 533 18 45 9 22 25,633 7,813 CampusLink LT™ I/O Riser Aluminum Interlocking Armor with Black Inner Jacket & Colored Outer Jacket (1Al 2J - GEL) DRLDBAJ series | OFCR / FT4 Fiber Count Range Recommended Fiber Count Recommended Part Number # of Buffer Tubes Diameter Approx. Cable Weight Bend Radius | Load Bend Radius | No Load Max. Reel Length Prysmian* Inches mm lb/kft kg/km Inches cm inches cm feet meters 6 - 48 6 DRLTBAJ-12-AA-006-BB 5 0.73 18.5 204 303 15 37 7 19 14,656 4,467 12 DRLTBAJ-12-AA-012-BB 24 DRLTBAJ-12-AA-048-BB 36 DRLTBAJ-12-AA-036-BB 48 DRLTBAJ-12-AA-048-BB 72 72 DRLTBAJ-12-AA-072-BB 6 0.76 19.2 219 326 15 38 8 19 10,827 3,300 96 96 DRLTBAJ-12-AA-096-BB 8 0.83 21.2 269 401 17 42 8 21 11,752 3,582 120 120 DRLTBAJ-12-AA-120-BB 10 0.90 22.8 349 519 18 46 9 23 8,235 2,510 144 144 DRLTBAJ-12-AA-144-BB 12 1.00 25.4 399 594 20 51 10 25 8,235 2,510 * Where AA equals glass type and BB equals attenuation Installation Maximum installation load: 600 lbf (2700 N) Maximum operation load: 180 lbf (800 N) Note. Cable damage may occur if installation temperature limits are exceeded; therefore, Prysmian recommends storing I/O cables in appropriate temperature conditions ≥ 24 hours prior to placement. Temperature Range Shipping and Storage: -58° F to +158° F (-50° C to +70° C) Installation: +14° F to +140° F (-10° C to +60° C) Operation: -58° F to +158° F (-50° C to +70° C) CampusLink LT™ Loose Tube Indoor/Outdoor Riser Rated Cable with Gel-Filled Buffer Tubes Prysmian 4 Tesseneer Drive, Highland Heights, KY 41076 na.prysmian.com TLS-DS-B-301-0625 INDOOR/OUTDOOR CABLES 106
Powered by Prysmian North America
Datacom Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait