Miscellaneous Products RW90 XLPE, Low-Voltage Power, 600 V CSA Type RW90, Single Conductor, High Speed, Copper Product Construction: Conductor: • 14 AWG thru 750 kcmil annealed Class B compressed stranded soft drawn plain copper • 14 AWG thru 10 AWG solid plain copper Insulation: • Heat- and moisture-resistant, low temperature Cross-linked Polyethylene (XLPE), Type RW90 (-40°C) • Color code: 14 AWG, 12 AWG, 10 AWG (solid) - black, white, red, blue, green, yellow, orange, brown; 10 AWG - black, white, red, blue, green; 8 AWG thru 2 AWG - black, white, red, blue, green; 1 AWG and larger - black (other colors available subject to minimum order quantity) Print: • GENERAL CABLE® (PLANT OF MFG) 1C SIZE (AWG OR KCMIL)(MM2) HIGH SPEED CU XLPE 600 V RW90 CSA (-40C) YEAR OF MFG SEQUENTIAL METER MARKING NOTE: For black insulation, add - SR COND. SIZE (AWG or kcmil) 14 14 12 12 10 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 300 350 400 500 600 750 1000 STRAND** 1 7/.0240 1 7/.0302 1 7/.0381 7/.0481 7/.0606 7/.0772 7/.0867 7/.0974 19/.0664 19/.0745 19/.0837 19/.0940 19/.1055 37/.0822 37/.0900 37/.0972 37/.1040 37/.1162 61/.0992 61/.1109 61/.1280 COND. CONDUCTOR O.D. 0.064 0.071 0.080 0.089 0.101 0.113 0.142 0.178 0.225 0.252 0.283 0.322 0.360 1.62 1.80 2.04 2.26 2.57 2.87 3.61 4.52 5.72 6.40 7.19 8.18 9.14 NOMINAL Options: • For 1000 volt applications, use RWU90 • PVC jacket (FT1 rating) Applications: • In accordance with Canadian Electrical Code (CEC), Part 1 • For wiring exposed to the weather (black color only) • For use in raceways (except cable trays) in dry, damp or wet locations in accordance with Canadian Electrical Code (CEC) • Refer to CEC Table 19 for conditions of use Features and Benefits: • Rated 90°C wet and dry • Meets cold bend and cold impact tests at -40°C • High Speed (HS) cable features a specially designed XLPE insulation that allows for fast and easy cable pulls Compliances: Industry Compliances: • CSA Standard C22.2 No. 38 • CSA Approval File Number 156400 Packaging: • Available in various standard lengths MIN. AVERAGE INS. THICKNESS 0.030 0.030 0.030 0.030 0.030 0.030 0.045 0.045 0.045 0.045 0.045 0.055 0.055 NOMINAL CABLE DIAMETER 0.410 10.41 0.055 0.460 11.68 0.055 0.510 12.95 0.055 0.560 14.22 0.065 0.610 15.49 0.065 0.660 16.76 0.065 0.710 18.03 0.065 0.790 20.07 0.065 0.870 22.10 0.080 0.970 24.64 0.080 1.120 28.45 0.080 Dimensions and weights are nominal; subject to manufacturing and industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** For compact-stranded constructions, the number of wires may be reduced as follows: 19-wire constructions - 18 wires minimum 37-wire constructions - 35 wires minimum 61-wire constructions - 58 wires minimum *** Based on CEC Part 1, Table 2 for three conductors in raceway (conduit). For underground installations, refer to CEC Rule 4-004 for ampacity rating. **** For 3 wires, 120/240 V and 120/208 V residential services or subservices, the allowable ampacity for 2/0 AWG shall be 200A. In this case, the 5% adjustment of Rule 8-106(1) cannot be applied. 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.40 1.40 1.40 1.40 1.40 1.65 1.65 1.65 1.65 1.65 2.03 2.03 2.03 0.126 0.133 0.142 0.151 0.163 0.175 0.236 0.272 0.319 0.346 0.377 3.20 3.38 3.61 3.84 4.14 4.45 5.99 6.91 8.10 8.79 9.58 COPPER WEIGHT 12 12 20 20 31 32 50 78 18 18 29 29 46 47 75 NET WEIGHT INCHES mm INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km 14 AWG - 1000 kcmil CONDUCTORS 0.76 0.436 11.07 0.477 12.12 0.522 13.26 0.572 14.53 0.628 15.95 0.696 17.68 0.749 19.02 0.799 20.29 0.844 21.44 0.927 23.55 1.038 26.37 1.140 28.96 1.289 32.74 129 163 200 258 326 411 518 653 772 926 1081 1235 1544 1883 2316 3088 117 192 243 298 384 485 612 771 972 1149 1379 1609 1838 2298 2802 3447 4596 17 18 25 26 37 39 62 93 147 183 220 281 359 448 559 699 828 988 1147 1305 1622 1986 2430 3218 26 26 37 38 56 58 93 138 218 272 327 417 534 666 832 1041 1233 1470 1707 1943 2414 2956 3617 4789 Electric Utility AMPACITY*** 30°C AMBIENT 25 25 30 30 40 40 55 75 95 115 130 145 170 195 225 260 290 320 350 380 430 425 535 615 140
Powered by Prysmian North America
Electric Utility (CA)
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait