Low-Voltage Power Cable ® Electric Utility PowrServ XL Underground Distribution Cable 600 V Quadruplex Al Conductor XLPE Insulation, UL Type USE-2 Product Construction: Complete Cable: Quadruplex 600 V PowrServ® XL cables consist of three phase conductors and one neutral conductor, all of which are insulated with extruded lead-free Cross-linked Polyethylene (XLPE). The cables are twisted together to form a quadruplex assembly. These XLPE insulated cables are manufactured and tested in accordance with ANSI/ICEA S-105-692 and UL 854, listed as a Type USE-2 cable. Conductors: Class B or SIW compressed 1350-H19 aluminum. Insulation: The insulation is extruded lead-free Cross-linked Polyethylene (XLPE). The three phase conductors are black, and the neutral conductor is black, identified by three extruded yellow stripes. Phase Identification: Phase identification is provided by means of white print legend markings, “Phase A” marking, and sequential footage markings on one phase conductor, white print legend markings and “Phase B” marking on another phase conductor, white print legend markings and “Phase C” marking on another phase conductor, and white print legend markings and three extruded yellow stripes on the neutral conductor. Features and Benefits: 600 V PowrServ XL underground distribution cables are suitable for direct burial or installations in ducts and are resistant to abrasion, impact and sunlight. For NEC- complying applications, the maximum conductor operating temperature is 90°C in wet or dry locations. This cable is also suitable for non- code-complying installations with a maximum conductor temperature of 90°C in wet or dry locations. Applications: PowrServ XL underground distribution cable is intended for use in underground systems operated at 600 volts or less. Options: • Aluminum 1350-H16 or H26 (¾ Hard) stranded conductor • Copper conductors • Series 8000 aluminum alloy conductor • Sizes 250 through 500 kcmil available with thin wall (0.080") insulation • High-molecular-weight Polyethylene (PE) insulation, 75˚C rating • Type RHH/RHW-2 per UL 44 • Other phase identification methods • Combined Duct & Cable factory-installed in extruded HDPE duct • MasterPak® reel-less packaging For more information, contact your General Cable sales representative or e-mail [email protected]. POWRSERV XL QUADRUPLEX CABLE—XLPE INSULATION—600 VOLTS AMPACITY (2) PHASE CONDUCTOR CODE WORD Tulsa/XP/EYS Dyke/XP/EYS Wittenberg/XP/EYS Notre Dame/XP/EYS Purdue/XP/EYS Syracuse/XP/EYS Lafayette/XP/EYS Swarthmore/XP/EYS Davidson/XP/EYS Wake Forest/XP/EYS Earlham/XP/EYS Rust/XP/EYS Niagara/XP/EYS Wofford/XP/EYS AWG OR kcmil 4 2 2 SIZE NO. OF WIRES (1) THKN. INCHES INS. AWG OR kcmil 7 0.060 4 7 0.060 4 7 0.060 2 1/0 19 0.080 2 NEUTRAL CONDUCTOR SIZE WIRES NO. OF THKN. INCHES INS. INCHES EFF. O.D. LB/1000 FT AL TOTAL APPROX. WEIGHT DIRECT BURIED DUCT IN PACKAGING 1000 FT REEL (3) 7 0.060 0.83 157 253 125 80 NR 32.24 7 0.060 0.94 226 340 160 105 NR 32.24 7 0.060 0.97 250 369 160 105 NR 36.24 7 0.060 1.17 360 529 205 140 NR 42.26 1/0 19 0.080 1/0 19 0.080 1.24 397 583 205 140 NR 42.26 2/0 19 0.080 1 19 0.080 1.29 454 651 230 170 NR 42.26 2/0 19 0.080 2/0 19 0.080 1.34 501 707 230 170 NR 45.28 3/0 19 0.080 1/0 19 0.080 1.40 573 791 265 195 NR 45.28 3/0 19 0.080 3/0 19 0.080 1.46 631 860 265 195 NR 45.28 4/0 19 0.080 2/0 19 0.080 1.53 722 965 300 220 NR 50.32 4/0 19 0.080 4/0 19 0.080 1.59 796 1052 300 220 NR 50.32 250† Slippery Rock/XP/EYS 350† 350† 500† 37 0.095 3/0 19 0.080 1.72 863 1170 330 245 NR 50.32 37 0.095 4/0 19 0.080 1.91 1187 1535 395 300 NR 58.32 37 0.095 350 37 0.095 2.01 1316 1716 395 300 NR 58.32 37 0.095 350 37 0.095 2.28 1739 2182 475 375 NR 66.36 (1) Actual number of wires may differ for compressed round stranded aluminum conductors using single input wire (SIW). (2) Ampacities are for non-code-complying installations. For installations covered by National Electrical Code (NEC), see the appropriate section of the NEC. Ampacity based on earth thermal resistivity of 90˚C-cm/watt, 90˚C conductor temp., 20˚C earth ambient temperature, 100% load factor and 36” depth of burial. Values based on no current in the neutral conductor. For specific ampacities, contact your General Cable sales representative. (3) Reel sizes may vary. MasterPak reel-less packaging is available - see Section 6 for description and typical dimensions for selected low-voltage products. † Available with thin wall (0.080”) insulation. Dimensions and weights not designated minimum or maximum are nominal values and subject to manufacturing tolerances. In this context, weight means mass. [email protected] 15