Industrial Automation ® SPEC 9605 October, 2014 CCW Armored Power, 3/C VFD and 4/C CATALOG NUMBER 9605.01403318 9605.01404216 9605.01404318 9605.01203316 9605.01204316 9605.01003314 9605.01004314 9605.00803314 9605.00804110 9605.00804212 9605.00603312 9605.00604108 9605.00604210 9605.00403312 9605.00404108 9605.00404210 9605.00203310 9605.00204106 9605.00204208 9605.00103310 9605.00104106 9605.11003310 9605.11004106 9605.21003310 9605.21004106 9605.31003308 9605.31004104 9605.41003308 9605.41004104 9605.25004104 9605.35003307 9605.35003306 9605.35004103 9605.50004102 9605.75003305 9605.75003304 9605.75004101 COND. SIZE (AWG/kcmil) (2.08 mm²) (5.26 mm²) (8.36 mm²) (13.3 mm²) (21.2 mm²) (33.6 mm²) (53.5 mm²) 2/0 (19/W) (67.4 mm²) 3/0 (19/W) (85.0 mm²) 4/0 (19/W) (107 mm²) 9605.25003308 250 (37/W) (127 mm²) 350 (37/W) (177 mm²) 9605.50003306 500 (37/W) (253 mm²) 750 (61/W) (380 mm²) 9605.100031110 1000 (61/W) (507 mm²) 9605.100041110 (42.4 mm²) 1/0 (19/W) 1 (19/W) 2 (7/W) 4 (7/W) 6 (7/W) 8 (7/W) (3.31 mm²) 10 (7/W) 12 (7/W) 14 (7/W) NO. OF COND. 3 4 4 3 4 3 4 3 4 4 3 4 4 3 4 4 3 4 4 3 4 3 4 3 4 3 4 3 4 3 4 3 3 4 3 4 3 3 4 3 4 mils mm 30 30 30 30 30 30 30 45 45 45 45 45 45 45 45 45 45 45 45 55 55 55 55 55 55 55 55 55 55 65 65 65 65 65 65 65 80 80 80 80 80 INSULATION THICKNESS BARE GROUND (AWG) 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.14 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.65 1.65 1.65 1.65 1.65 1.65 1.65 2.03 2.03 2.03 3 x #18 2 x #16 3 x #18 3 x #16 3 x #16 3 x #14 3 x #14 3 x #14 1 x #10 2 x #12 3 x #12 1 x #8 2 x #10 3 x #12 1 x #8 2 x #10 3 x #10 1 x #6 2 x #8 3 x #10 1 x #6 3 x #10 1 x #6 3 x #10 1 x #6 3 x #8 1 x #4 3 x #8 1 x #4 3 x #8 1 x #4 3 x #7 3 x #6 1 x #3 3 x #6 1 x #2 3 x #5 3 x #4 1 x #1 2.03 1 x #1/0 2.03 1 x #1/0 NOMINAL CORE O.D. 0.33 0.37 0.37 0.45 0.41 0.45 0.50 0.58 0.57 0.58 0.66 0.66 0.68 0.77 0.76 0.80 0.92 0.89 0.92 1.04 1.00 1.12 1.09 1.23 1.21 1.36 1.33 1.49 1.48 1.64 1.66 1.63 1.89 1.94 2.14 2.37 2.32 2.61 2.67 3.07 Dimensions and weights are nominal; subject to industry tolerances. ¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22. ² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16). 8.4 8.4 ARMOR O.D. 0.53 0.51 11.4 9.4 0.58 9.4 0.58 0.67 10.4 0.62 11.4 12.7 0.67 0.71 14.7 0.80 14.5 0.77 14.7 0.80 16.8 0.89 16.8 0.88 17.3 0.89 19.6 19.3 20.3 23.4 22.6 23.4 26.4 25.4 28.4 27.7 31.2 30.7 34.5 33.8 37.8 37.6 41.7 42.2 41.4 48.0 0.97 1.00 1.02 1.15 1.16 1.15 1.29 1.24 1.37 1.34 1.51 1.47 1.65 1.60 1.78 1.74 1.96 1.96 1.95 2.19 49.3 2.28 54.4 60.2 58.9 2.49 2.75 2.71 66.3 3.03 67.8 3.11 78.0 3.63 13.5 13.0 14.7 14.7 17.0 15.7 17.0 18.0 20.3 19.6 20.3 22.6 22.4 22.6 24.6 25.4 25.9 29.2 29.5 29.2 32.8 31.5 34.8 34.0 38.4 37.3 41.9 40.6 45.2 44.2 49.8 49.8 49.5 55.6 57.9 63.2 69.9 68.8 77.0 79.0 92.2 NOMINAL THICKNESS 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 60 60 60 60 60 60 60 60 60 75 75 75 75 75 85 85 85 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.27 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.52 1.91 1.91 1.91 1.91 1.91 2.16 2.16 2.16 JACKET UL Type MC-HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant Direct Burial, UL Marine Shipboard Cable, ABS CWCMC, Arctic-Grade NOMINAL OVERALL O.D. 0.64 0.62 0.69 0.69 0.78 0.73 0.78 0.81 0.90 0.88 0.90 0.99 0.99 0.99 1.08 1.11 1.13 1.26 1.27 1.26 1.40 1.34 1.48 1.44 1.64 1.58 1.78 1.73 1.91 1.87 2.09 2.09 2.09 2.35 2.44 2.65 2.92 2.86 3.21 3.30 3.81 16.3 15.7 17.5 17.5 19.8 18.5 19.8 20.6 22.9 22.4 22.9 25.1 25.1 25.1 27.4 28.2 28.7 32.0 32.3 32.0 35.6 34.0 37.6 36.6 41.7 40.1 45.2 43.9 48.5 47.5 53.1 53.1 53.1 59.7 62.0 67.3 74.2 72.6 81.5 83.8 96.8 SECTIONAL AREA1 INCHES mm INCHES mm mils mm INCHES mm SQ. IN. 0.33 0.33 0.30 0.38 0.38 0.48 0.42 0.48 0.52 0.64 0.61 0.64 0.78 0.78 0.78 0.93 0.97 1.02 1.26 1.27 1.26 1.56 1.43 1.74 1.65 2.14 1.99 2.52 2.38 2.87 2.75 3.43 3.43 3.43 4.34 4.68 5.52 6.70 6.42 8.09 8.55 11.40 CROSS- APPROXIMATE NET WEIGHT LBS/1000 FT 163 221 226 243 291 305 354 392 473 491 534 641 679 716 860 950 1,013 1,267 1,371 1,119 1,526 1,496 1,862 1,801 2,351 2,262 2,921 2,722 3,491 3,195 4,142 4,284 4,329 5,536 6,035 7,704 8,854 8,926 11,449 11,611 15,377 kg/1000 m 242 330 336 362 433 454 527 583 704 731 795 954 1,012 1,066 1,280 1,415 1,507 1,885 2,043 1,666 2,272 2,226 2,771 2,681 3,498 3,367 4,346 4,051 5,194 4,755 6,164 6,376 6,443 8,238 8,981 11,464 13,176 13,293 17,037 17,280 22,883 AMPACITY @ 30°C AMBIENT² 15 15 15 20 20 30 30 55 44 44 75 60 60 95 76 76 130 104 104 150 120 170 136 195 156 225 180 260 208 290 232 350 350 280 430 344 535 535 428 615 492 90°C 79
Powered by Prysmian North America
Industrial Automation Solutions
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait