Industrial Automation ® CCW SPEC 9815 October, 2014 Armored Power, 8 kV 133%, Shielded, 3/C VFD UL Type MC-HL or MV-105, CSA Type HL, EPR, 105°C, Cable Tray Use, Sunlight-Resistant Direct Burial, ABS CWCMC COND. SIZE CATALOG NUMBER AWG (kcmil) 9815.00603310 6 (7/W) 9815.00403310 4 (7/W) 9815.00203310 2 (7/W) 9815.00103308 1 (19/W) 9815.11003308 1/0 (19/W) 9815.21003308 2/0 (19/W) 9815.41003307 4/0 (19/W) 9815.25003306 250 (37/W) 9815.35003306 350 (37/W) 9815.50003305 500 (37/W) 9815.75003304 750 (61/W) 9815.10003304 1000 (61/W) (107 mm²) (127 mm²) (177 mm²) (253 mm²) (380 mm²) (507 mm²) NO. OF COND. INSULATION THICKNESS NOMINAL O.D. OVER INSULATION GROUND BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. mils mm INCHES mm AWG INCHES mm INCHES mm mils mm INCHES mm 140 3.6 0.48 12.2 3 x #10 1.20 30.5 1.60 40.6 60 1.52 1.73 140 3.6 0.53 13.5 3 x #10 1.29 32.8 1.70 43.2 60 1.52 1.83 140 3.6 0.58 14.7 3 x #10 1.42 36.1 1.85 47.0 60 1.52 1.98 140 3.6 0.62 15.7 3 x #8 1.52 38.6 1.93 49.0 60 1.52 2.06 140 3.6 0.65 16.5 3 x #8 1.61 40.9 2.03 51.6 60 1.52 2.16 140 3.6 0.69 17.5 3 x #8 1.66 42.2 2.14 54.4 60 1.52 2.27 140 3.6 0.79 20.1 3 x #7 1.87 47.5 2.40 61.0 75 1.91 2.56 140 3.6 0.85 21.6 3 x #6 2.06 52.3 2.59 65.8 75 1.91 2.75 140 3.6 0.94 23.9 3 x #6 2.15 54.6 2.85 72.4 75 1.91 3.01 140 3.6 1.06 26.9 3 x #5 2.44 62.0 3.19 81.0 85 2.16 3.37 140 3.6 1.26 32.0 3 x #4 3.19 81.0 3.68 93.5 85 2.16 3.86 NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT 43.9 1,350 46.5 1,600 50.3 2,000 52.3 2,275 54.9 2,600 57.7 2,950 65.0 4,025 69.9 4,600 76.5 5,800 kg/1000 m 3/C WITH GROUND MC-HL OR MV-105, 140 MILS EPR, 8 kV 133% INSULATION LEVEL (13.3 mm²) 3 (21.2 mm²) 3 (33.6 mm²) 3 (42.4 mm²) 3 (53.5 mm²) 3 (67.4 mm²) 3 3 3 3 3 3 3 AMPACITY IN AIR¹ 2,009 105 2,381 135 2,976 185 3,386 210 3,869 240 4,390 275 5,990 360 6,846 400 8,631 490 85.6 7,800 11,608 600 98.0 10,750 15,998 745 140 3.6 1.42 36.1 3 x #4 3.48 88.4 3.98 101.1 85 2.16 4.16 105.7 13,550 20,165 860 DIRECT BURIAL² 120 155 200 225 255 290 375 410 495 590 720 810 Dimensions and weights are nominal; subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. 91
Powered by Prysmian North America
Industrial Automation Solutions
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait