Industrial Automation ® CCW SPEC 9805 October, 2014 Armored Power, 5 kV 133%/8 kV 100%, Shielded, 3/C VFD UL Type MC-HL or MV-105, CSA Type HL, EPR, 105°C, Cable Tray Use Sunlight-Resistant, Direct Burial, UL Marine Shipboard Cable, ABS CWCMC, Arctic-Grade NOMINAL CATALOG NUMBER 9805.00603310 9805.00403310 9805.00203310 9805.00103308 COND. SIZE (AWG/kcmil) (33.6 mm²) 1 (19/W) (42.4 mm²) 9805.11003308 1/0 (19/W) 9805.21003308 2/0 (19/W) 9805.41003307 4/0 (19/W) 9805.25003306 250 (37/W) 9805.35003306 350 (37/W) 9805.50003305 500 (37/W) 9805.75003304 750 (61/W) 9805.10003304 1000 (61/W) (53.5 mm²) (67.4 mm²) (107 mm²) (127 mm²) (177 mm²) (253 mm²) (380 mm²) (507 mm²) (21.2 mm²) 2 (7/W) (13.3 mm²) 4 (7/W) COND. mils mm INCHES mm 3 115 2.9 0.43 0.48 0.53 0.57 0.60 0.64 0.74 0.80 0.89 1.01 1.19 1.34 NO. OF INSULATION THICKNESS INSULATION NOMINAL O.D. OVER GROUND (AWG) 10.9 3 x #10 BARE NOMINAL CORE O.D. ARMOR O.D. THICKNESS JACKET OVERALL O.D. INCHES mm INCHES mm mils mm INCHES mm 1.15 29.2 1.37 34.8 50 1.27 1.48 37.6 NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT 1,121 kg/1000 m IN AIR¹ 3/C WITH GROUND MC-HL OR MV-105, 115 MILS EPR, 5 kV 133% AND 8 kV 100% INSULATION LEVEL 6 (7/W) 1,668 3 3 3 3 3 3 3 3 3 3 3 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 115 2.9 12.2 3 x #10 1.24 31.5 1.51 38.4 60 1.52 1.65 13.5 3 x #10 1.37 34.8 1.64 41.7 60 1.52 1.78 14.5 3 x #8 15.2 3 x #8 16.3 3 x #8 18.8 3 x #7 20.3 3 x #6 22.6 3 x #6 25.7 3 x #5 30.2 3 x #4 34.0 3 x #4 1.47 37.3 1.69 42.9 60 1.52 1.82 1.56 39.6 1.78 45.2 60 1.52 1.91 1.61 40.9 1.92 48.8 60 1.52 2.05 1.82 46.2 2.15 54.6 60 1.52 2.28 2.01 51.1 2.23 56.6 60 1.52 2.36 2.10 53.3 2.45 62.2 75 1.91 2.61 2.39 60.7 2.75 69.9 75 1.91 2.92 3.07 78.0 3.32 84.3 85 2.16 3.50 3.43 87.1 3.76 95.5 85 2.16 3.94 41.9 45.2 46.2 48.5 52.1 57.9 59.9 66.3 74.2 1,418 1,731 1,978 2,259 2,626 3,650 4,060 5,045 2,110 88 115 2,576 154 2,944 180 3,362 205 3,908 240 5,432 320 6,042 355 7,508 440 7,137 10,621 545 88.9 10,268 15,280 685 100.1 13,051 19,422 790 Dimensions and weights are nominal; subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. ³ For 8 kV ampacities, refer to NEC Tables 310.60(C)(71) and 310.60(C)(83) for cables listed 5,001-35,000 volts. 5 kV³ AMPACITY DIRECT 115 150 190 215 245 280 360 395 475 570 700 785 BURIAL² 89
Powered by Prysmian North America
Industrial Automation Solutions
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait