Industrial Automation ® CCW CATALOG NUMBER 9700.00803312 9700.00603310 9700.00403310 9700.00203310 SPEC 9700 July, 2014 Armored Power, 2.4 kV, Nonshielded, 3/C VFD UL Type MC-HL or MV-90, EPR, 105°C, Cable Tray Use, Sunlight-Resistant Direct Burial, ABS CWCMC COND. SIZE AWG (kcmil) (8.36 mm²) 3 90 2.3 0.36 9.1 3 x #12 0.77 19.6 0.97 24.6 50 1.27 1.08 27.4 6 (7/W) 8 (7/W) (13.3 mm²) 3 90 2.3 0.38 9.6 3 x #10 0.85 21.6 1.06 26.9 50 1.27 1.17 29.7 4 (7/W) 9700.00103308 1 (19/W) 9700.11003308 1/0 (19/W) 9700.21003308 2/0 (19/W) 9700.41003307 4/0 (19/W) 9700.25003307 250 (37/W) 9700.35003306 350 (37/W) 9700.50003305 500 (37/W) 9700.75003304 750 (61/W) 9700.10003304 1000 (61/W) (33.6 mm²) 3 90 2.3 0.48 12.1 3 x #10 1.10 27.9 1.34 34.0 50 1.27 1.45 36.8 1,275 1,897 140 (42.4 mm²) 3 90 2.3 0.52 13.1 3 x #8 1.16 29.5 1.42 36.1 50 1.27 1.53 38.9 1,525 2,269 160 (53.5 mm²) 3 90 2.3 0.55 13.9 3 x #8 1.23 31.2 1.51 38.4 60 1.52 1.65 41.9 1,840 2,738 185 (67.4 mm²) 3 90 2.3 0.59 14.9 3 x #8 1.33 33.8 1.60 40.6 60 1.52 1.73 43.9 2,165 3,222 215 (107 mm²) 3 90 2.3 0.69 17.4 3 x #7 1.53 38.9 1.83 46.5 60 1.52 1.96 49.8 3,080 4,584 285 (127 mm²) 3 90 2.3 0.74 18.7 3 x #7 1.64 41.7 1.96 49.8 60 1.52 2.09 53.1 3,475 5,171 320 (177 mm²) 3 90 2.3 0.83 21.0 3 x #6 1.86 47.2 2.19 55.6 60 1.52 2.32 58.9 4,710 7,009 395 (253 mm²) 3 90 2.3 0.95 24.0 3 x #5 2.10 53.3 2.45 62.2 75 1.91 2.61 66.3 6,410 9,539 485 (380 mm²) 3 90 2.3 1.12 28.3 3 x #4 2.51 63.8 2.93 74.4 75 1.91 3.10 78.7 9,225 13,728 615 (507 mm²) 3 90 2.3 1.27 32.2 3 x #4 2.90 73.7 3.41 86.6 80 2.03 3.59 91.2 12,080 17,977 705 (21.2 mm²) 3 90 2.3 0.43 10.8 3 x #10 0.97 24.6 1.19 30.2 50 1.27 1.30 33.0 2 (7/W) COND. mils mm INCHES mm AWG INCHES mm INCHES mm mils mm INCHES mm 3/C WITH GROUND MC-HL OR MV-90, 90 MILS EPR, 2.4 kV, YELLOW JACKET NO. OF INSULATION THICKNESS NOMINAL O.D. OVER INSULATION GROUND BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT 570 kg/1000 m 848 745 1,109 AMPACITY IN AIR¹ 59 79 965 1,436 105 DIRECT BURIAL² 85 105 135 180 200 230 260 335 365 440 530 650 730 Dimensions and weights are nominal, subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 90°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 90°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. 85
Powered by Prysmian North America
Industrial Automation Solutions
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait