Industrial Automation ™ SPEC 4780 November, 2013 TC-Flex Tray Cable 14 AWG (2,5 mm² Product Construction: Conductors: • 14 AWG (2,5 mm²) thru 10 AWG (6,0 mm²) fully annealed flexible stranded bare copper with Class 5 stranding per EN 60228 (IEC 60228) Insulation: • Polyvinyl Chloride (PVC) insulation with Polyamide (nylon) jacket per UL 83 Conductor Identification: • Conductors are black with printed numbers and green/yellow grounding conductor Cable Assembly: • Conductors cabled with non-hygroscopic fillers to make the cable suitably round Jacket: • Black, flexible, flame-retardant, sunlight- and oil- resistant Polyvinyl Chloride (PVC) jacket Print: • GENERAL CABLE® TC-FLEX™ XX/C XXAWG (XXMM2) (UL) TC-ER TYPE THHN/THWN 90˚C DRY 75˚C WET 600 V SUN RES DIR BUR OIL RES I/II OR MTW OR WTTC 1000 V 90˚C DRY c(UL) CIC/TC PVC/N 90˚C FT4 --- CSA AWM I/II A/B 90˚C 1000 V – ROHS CE – MADE IN USA DAY/MONTH/YEAR OF MFG SEQUENTIAL FOOTAGE MARKER Minimum Bending Radius: • 4x O.D. for fixed installation • 8x O.D. for flexing applications Torsion: • 10,000 cycles at -40°C, +/- 150° twist per meter, cable weight compensated to 20 meters Applications: • In free air, raceways or direct burial • (UL) WTTC cables for use up to 1000 V in wind turbine generator applications in accordance with UL Subject 6140 • (UL) TC-ER cables for use up to 600 V as power and control cables in accordance with NEC® Article 336 • (UL) MTW cables for machine tool and wire up to 600 V as power and control cables in accordance with UL 1063 • (CSA) CIC/TC cables for use up to 600 V in cable trays and other applications when installed in accordance with the Canadian Electrical Code, Part I • (CSA) AWM cables for use up to 1000 V as equipment wiring in accordance with the Canadian Electrical Code, Part I Specifications: Design Adherence: • UL 66 & UL 83/CSA C22.2 No. 75-08 Thermoplastic Insulated Wires • UL 1063/MTW Machine Tool Wire • UL 1277 Power and Control Tray Cables • UL 2277 Wind Turbine Tray Cables • CSA C22.2 No. 230-09 Tray Cables • CSA C22.2 No. 239-09 Control and Instrumentation Cables • CSA C22.2 No. 210-11 Appliance Wiring Material Products Flame Tests: • IEEE 1202/CSA FT4 Compliances: • Type TC-ER 90°C Dry, 75°C Wet, 600 V • Type MTW • Type WTTC 90°C, 1000 V • Type CIC/TC 90°C, 600 V • Type AWM I/II A/B, 90°C, 1000 V FT4 • RoHS Compliant 4780.03012 4780.04012 4780.05012 4780.07012* 4780.09012* 4780.12012* 4780.19012* 4780.25012* 4780.30012* 4780.37012* 4780.03010 4780.04010 4780.05010 4780.07010* 4780.09010* 4780.12010* 4780.19010* 4780.25010* 4780.30010* 3 4 5 7 9 12 19 25 30 37 3 4 5 7 9 12 19 25 30 CATALOG NUMBER 4780.03014 4780.04014 4780.05014 4780.07014 4780.09014* 4780.12014* 4780.19014* 4780.25014* 4780.30014* 4780.37014* NO. OF COND. INC. GRND. 3 4 5 7 9 12 19 25 30 37 NOM. INS. THICKNESS NOM. JACKET THICKNESS CABLE O.D. NOM. NOM. COPPER WEIGHT INCHES mm INCHES mm INCHES mm 1000 FT kg/km 1000 FT kg/km 14 AWG (2,50 mm²) 46 Strands 0.021 0.53 0.048 1.22 0.375 9.5 0.021 0.53 0.048 1.22 0.408 10.4 0.021 0.53 0.048 1.22 0.442 11.2 0.021 0.53 0.048 1.22 0.502 12.8 0.021 0.53 0.063 1.60 0.583 14.8 0.021 0.53 0.063 1.60 0.647 16.4 0.021 0.53 0.063 1.60 0.774 19.7 0.021 0.53 0.085 2.16 0.915 23.2 0.021 0.53 0.085 2.16 0.965 24.5 0.021 0.53 0.085 2.16 1.036 26.3 0.021 0.53 0.048 1.22 0.435 11.1 0.021 0.53 0.048 1.22 0.476 12.1 0.021 0.53 0.048 1.22 0.517 13.1 0.021 0.53 0.063 1.60 0.622 15.8 0.021 0.53 0.063 1.60 0.684 17.4 0.021 0.53 0.063 1.60 0.763 19.4 0.021 0.53 0.085 2.16 0.964 24.5 0.021 0.53 0.095 2.41 1.103 28.0 0.021 0.53 0.095 2.41 1.164 29.6 0.021 0.53 0.095 2.41 1.252 31.8 0.027 0.69 0.048 1.22 0.491 12.5 0.027 0.69 0.063 1.60 0.567 14.4 0.027 0.69 0.063 1.60 0.618 15.7 0.027 0.69 0.063 1.60 0.705 17.9 0.027 0.69 0.063 1.60 0.779 19.8 0.027 0.69 0.085 2.16 0.915 23.2 0.027 0.69 0.095 2.41 1.119 28.4 0.027 0.69 0.095 2.41 1.259 32.0 0.027 0.69 0.095 2.41 1.331 33.8 43 58 72 101 130 174 275 362 435 536 12 AWG (4,0 mm²) 56 Strands 72 97 121 169 217 290 459 604 65 86 108 151 194 259 410 539 647 798 108 144 180 252 323 431 683 898 724 1,078 893 1,329 10 AWG (6,0 mm²) 82 Strands 109 146 182 255 327 437 162 217 271 379 487 650 1,092 691 1,029 910 1,354 1,625 85 106 128 170 226 289 432 587 126 158 190 253 336 429 642 874 686 1,021 826 1,229 123 155 188 269 335 431 183 231 280 401 498 642 1,057 1,275 689 1,025 901 1,341 1,572 1,897 172 234 284 381 477 654 1,007 1,293 1,524 256 348 422 568 710 973 1,499 1,925 2,268 Articles 336.80 and 392.11, Table 310.16 and are derated in accordance with NEC® LBS/ NOM. CABLE WEIGHT LBS/ AMP. @ 30°C AMBIENT¹ 18 18 18 18 16 16 12 12 10 10 25 25 25 25 20 20 17 17 14 14 35 35 35 35 30 30 25 20 20 * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ¹ Ampacities provided are for open cable runs, in a raceway, directly buried, or as aerial cable supported on a messenger in accordance with NEC® 310.15.B.2. 90°C ) – 10 AWG (6,0 mm² ) UL Type WTTC 1000 V or Type TC-ER 600 V or Type MTW and c(UL) CIC/TC 600 V FT4 or CSA AWM 90°C 1000 V, Flexible, Oil Res I/II, Sunlight- and Torsion-Resistant, Flame-Retardant, -40˚C to +90˚C 58
Powered by Prysmian North America
Industrial Automation Solutions
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait