SPEC 9600 October, 2014 CCW Armored Power, 3/C VFD and 4/C ® UL Type MC-HL, CSA Type HL, XLPE, 600 V, 90°C, Cable Tray Use, Sunlight-Resistant Direct Burial, UL Marine Shipboard Cable, ABS CWCMC CATALOG NUMBER 9600.01403318 9600.01404318 9600.01203316 9600.01204316 9600.01003314 9600.01004314 9600.00803314 9600.00804110 9600.00603312 9600.00604108 9600.00403312 9600.00404108 9600.00203310 9600.00204106 9600.00103310 9600.00104106 9600.11004106 (AWG/kcmil) 14 (7/W) (2.08 mm²) 12 (7/W) (3.31 mm²) 10 (7/W) (5.26 mm²) 8 (7/W) (8.36 mm²) 6 (7/W) (13.3 mm²) 4 (7/W) (21.2 mm²) 2 (7/W) (33.6 mm²) 1 (19/W) (42.4 mm²) 9600.11003310 1/0 (19/W) (53.5 mm²) 9600.21003310 2/0 (19/W) (67.4 mm²) 9600.21004106 9600.31003308 3/0 (19/W) (85.0 mm²) 9600.31004104 9600.41003308 4/0 (19/W) (107 mm²) 9600.41004104 9600.25003308 250 (37/W) (127 mm²) 9600.25004104 9600.35003307 350 (37/W) (177 mm²) 9600.35004103 9600.50003306 500 (37/W) (253 mm²) 9600.50004102 9600.75003305 750 (61/W) (380 mm²) 9600.75004101 9600.100031110 1000 (61/W) (507 mm²) 9600.100041110 COND. SIZE NO. OF COND. INSULATION THICKNESS mils mm GROUND (AWG) BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. NOMINAL SECTIONAL AREA¹ 3 30 0.76 3 x #18 0.33 8.4 0.53 13.5 50 1.27 0.64 16.3 0.33 4 30 0.76 3 x #18 0.37 9.4 0.58 14.7 50 1.27 0.69 17.5 0.38 3 30 0.76 3 x #16 0.37 9.4 0.58 14.7 50 1.27 0.69 17.5 0.38 4 30 0.76 3 x #16 0.45 11.4 0.67 17.0 50 1.27 0.78 19.8 0.48 3 30 0.76 3 x #14 0.41 10.4 0.62 15.7 50 1.27 0.73 18.5 0.42 4 30 0.76 3 x #14 0.45 11.4 0.67 17.0 50 1.27 0.78 19.8 0.48 3 45 1.14 3 x #14 0.50 12.7 0.71 18.0 50 1.27 0.81 20.6 0.52 4 45 1.14 1 x #10 0.58 14.7 0.80 20.3 50 1.27 0.90 22.9 0.64 3 45 1.14 3 x #12 0.58 14.7 0.80 20.3 50 1.27 0.90 22.9 0.64 4 45 1.14 1 x #8 0.66 16.8 0.89 22.6 50 1.27 0.99 25.1 0.78 3 45 1.14 3 x #12 0.68 17.3 0.89 22.6 50 1.27 0.99 25.1 0.78 4 45 1.14 1 x #8 0.77 19.6 0.97 24.6 50 1.27 1.08 27.4 0.93 3 45 1.14 3 x #10 0.80 20.3 1.02 25.9 50 1.27 1.13 28.7 1.02 4 45 1.14 1 x #6 0.92 23.4 1.15 29.2 50 1.27 1.26 32.0 1.26 3 55 1.40 3 x #10 0.92 23.4 1.15 29.2 50 1.27 1.26 32.0 1.26 4 55 1.40 1 x #6 1.04 26.4 1.29 32.8 50 1.27 1.40 35.6 1.56 3 55 1.40 3 x #10 1.00 25.4 1.24 31.5 50 1.27 1.34 34.0 1.43 4 55 1.40 1 x #6 1.12 28.4 1.37 34.8 50 1.27 1.48 37.6 1.74 3 55 1.40 3 x #10 1.09 27.7 1.34 34.0 50 1.27 1.44 36.6 1.65 4 55 1.40 1 x #6 1.23 31.2 1.51 38.4 60 1.52 1.64 41.7 2.14 3 55 1.40 3 x #8 1.21 30.7 1.47 37.3 60 1.52 1.58 40.1 1.99 4 55 1.40 1 x #4 1.36 34.5 1.65 41.9 60 1.52 1.78 45.2 2.52 3 55 1.40 3 x #8 1.33 33.8 1.60 40.6 60 1.52 1.73 43.9 2.38 4 55 1.40 1 x #4 1.49 37.8 1.78 45.2 60 1.52 1.91 48.5 2.90 CROSS- APPROXIMATE NET WEIGHT INCHES mm INCHES mm mils mm INCHES mm SQ. IN. LBS/1000 FT kg/1000 m AMBIENT² 163 226 243 291 305 354 392 473 534 641 242 15 336 15 362 20 433 20 454 30 527 30 583 55 704 44 795 75 954 60 716 1,066 95 860 1,280 76 1,013 1,507 130 1,267 1,885 104 1,119 1,666 150 1,526 2,272 120 1,496 2,226 170 1,862 2,771 136 1,801 2,681 195 2,351 3,498 156 2,262 3,367 225 2,921 4,346 180 2,722 4,051 260 3,491 5,194 208 3 65 1.65 3 x #8 1.48 37.6 1.74 44.2 60 1.52 1.87 47.5 — 3,195 4,755 290 4 65 1.65 1 x #4 1.64 41.7 1.96 49.8 60 1.52 2.09 53.1 — 4,142 6,164 232 3 65 1.65 3 x #7 1.66 42.2 1.96 49.8 60 1.52 2.09 53.1 — 4,284 6,376 350 4 65 1.65 1 x #3 1.89 48.0 2.19 55.6 75 1.91 2.35 59.7 — 5,536 8,238 280 3 65 1.65 3 x #6 1.94 49.3 2.28 57.9 75 1.91 2.44 62.0 — 6,035 8,981 430 4 65 1.65 1 x #2 2.14 54.4 2.49 63.2 75 1.91 2.65 67.3 — 7,704 11,464 344 3 80 2.03 3 x #5 2.37 60.2 2.75 69.9 75 1.91 2.92 74.2 — 8,854 13,176 535 4 80 2.03 1 x #1 2.61 66.3 3.03 77.0 85 2.16 3.21 81.5 — 11,449 17,037 428 3 80 2.03 1 x #1/0 2.67 67.8 3.11 79.0 85 2.16 3.30 83.8 — 11,611 17,280 615 4 80 2.03 1 x #1/0 3.07 78.0 3.63 92.2 85 2.16 3.81 96.8 — 15,377 22,883 492 Dimensions and weights are nominal; subject to industry tolerances. ¹ Cross-sectional area for cable tray fill is in accordance with NEC Section 392.22. ² Ampacities in accordance with NEC Article 310 and Table 310.15(B)(16). Note: Three (3) conductors, 6 AWG and smaller are also marked CSA Type RA90. One (1) AWG and larger are also marked CSA Type RA90. AMPACITY @ 30°C 90°C Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait