SPEC 9800 October, 2014 CCW Armored Power, 5 kV 133%/8 kV 100%, Shielded, 3/C VFD UL Type MC-HL or MV-105, CSA Type HL, EPR, 105°C, Cable Tray Use, Sunlight-Resistant Direct Burial, ABS CWCMC ® COND. SIZE CATALOG NUMBER AWG (kcmil) 9800.00603310 6 (7/W) (13.3 mm²) 9800.00403310 4 (7/W) (21.2 mm²) 9800.00203310 2 (7/W) (33.6 mm²) 9800.00103308 1 (19/W) (42.4 mm²) 9800.11003308 1/0 (19/W) (53.5 mm²) 9800.21003308 2/0 (19/W) (67.4 mm²) 9800.41003307 4/0 (19/W) (107 mm²) 9800.25003306 250 (37/W) (127 mm²) 9800.35003306 350 (37/W) (177 mm²) 9800.50003305 500 (37/W) (253 mm²) 9800.75003304 750 (61/W) (380 mm²) 9800.10003304 1000 (61/W) (507 mm²) NO. OF COND. INSULATION THICKNESS NOMINAL O.D. OVER INSULATION GROUND BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. mils mm INCHES mm AWG INCHES mm INCHES mm mils mm INCHES mm NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT kg/1000 m 5 kV³ AMPACITY IN AIR¹ DIRECT BURIAL² 3/C WITH GROUND MC-HL OR MV-105, 115 MILS EPR, 5 kV 133% AND 8 kV 100% INSULATION LEVEL 3 115 2.9 0.43 10.9 3 x #10 1.15 29.2 1.37 34.8 50 1.27 1.48 37.6 1,121 1,668 88 115 3 115 2.9 0.48 12.2 3 x #10 1.24 31.5 1.51 38.4 60 1.52 1.65 41.9 1,418 2,110 115 150 3 115 2.9 0.53 13.5 3 x #10 1.37 34.8 1.64 41.7 60 1.52 1.78 45.2 1,731 2,576 154 190 3 115 2.9 0.57 14.5 3 x #8 1.47 37.3 1.69 42.9 60 1.52 1.82 46.2 1,978 2,944 180 215 3 115 2.9 0.60 15.2 3 x #8 1.56 39.6 1.78 45.2 60 1.52 1.91 48.5 2,259 3,362 205 245 3 115 2.9 0.64 16.3 3 x #8 1.61 40.9 1.92 48.8 60 1.52 2.05 52.1 2,626 3,908 240 280 3 115 2.9 0.74 18.8 3 x #7 1.82 46.2 2.15 54.6 60 1.52 2.28 57.9 3,650 5,432 320 360 3 115 2.9 0.80 20.3 3 x #6 2.01 51.1 2.23 56.6 60 1.52 2.36 59.9 4,060 6,042 355 395 3 115 2.9 0.89 22.6 3 x #6 2.10 53.3 2.45 62.2 75 1.91 2.61 66.3 5,045 7,508 440 475 3 115 2.9 1.01 25.7 3 x #5 2.39 60.7 2.75 69.9 75 1.91 2.92 74.2 7,137 10,621 545 570 3 115 2.9 1.19 30.2 3 x #4 3.07 78.0 3.32 84.3 85 2.16 3.50 88.9 10,268 15,280 685 700 3 115 2.9 1.34 34.0 3 x #4 3.43 87.1 3.76 95.5 85 2.16 3.94 100.1 13,051 19,422 790 785 Dimensions and weights are nominal; subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. ³ For 8 kV ampacities, refer to NEC Tables 310.60(C)(71) and 310.60(C)(83) for cables listed 5001-35,000 volts. Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait