SPEC 5275 September, 2016 GenFree II High Speed ® 600 V, UL Type RHH/RHW-2-LSHF/USE-2 or 1000 V, c(UL) RW90 XLF LSZH XLPO, Low-Voltage Power, Unshielded LOW FRICTION TECHNOLOGY Product Construction: Conductor: • 14 AWG thru 1000 kcmil stranded annealed tinned copper per ASTM B33 • Compressed Class B stranding per ASTM B8 Insulation: • Low-Smoke, Zero-Halogen Cross-linked Polyolefin (LSZH XLPO), black • Colors available upon request Applications: • For use in closed environments or populated spaces such as auditoriums, arenas and health facilities where more stringent customer specifications for smoke and halogen-free materials are desired • Ideally suited for use in a broad range of commercial, industrial, transit and utility applications where reliability is a major concern, where maximum performance will be demanded and where space is limited • For use in free air, raceways or direct burial in accordance with NEC Features: • Rated at 90˚C wet or dry • Low-Smoke, Zero-Halogen insulation system • Smaller cable O.D. • High Speed low friction technology for easy cable pulling • Excellent electrical, thermal and physical properties • Excellent moisture resistance, exceeding UL 44 requirements • Excellent resistance to crush, compression cuts and heat deformation • Excellent flame resistance • Resistant to most oils and chemicals CATALOG NUMBER 17602.210014*† 17602.210012*† 17602.210010* 17602.210800* 17602.210600* 17602.210400* 17602.210200* 17602.215100* 17602.215200* 17602.215400* 17602.216000* 17602.216200* 17602.216500* 17602.217000* 17602.217500* (AWG/ kcmil) COND. SIZE Features (cont’d.): • UV/sunlight-resistant • Rated ST-1 for Limited Smoke per UL 44 on sizes 1/0 AWG and larger • Stable electrical properties over a broad temperature range • Excellent low temperature characteristics, meets cold bend and cold impact test at -40˚C Compliances: Industry Compliances: • National Electrical Code (NEC) • “FOR CT USE” on 1/0 AWG and larger in accordance with NEC • UL 44 Type RHH/RHW-2, UL File # E90494 • c(UL) Type RW90 1 kV UL File # E90494 • UL 854 Type USE-2, UL File # E90499 • UL Listed Low-Smoke, Halogen-Free per UL 2885 • Limited Smoke rating per UL 44 and UL 1685 • ICEA T-33-655 smoke, halogen and acid gas requirements • Halogen content of cable material does not exceed 0.2%, and acid gas equivalent does not exceed 2.0%, according to the test method of MIL-C-24643 • ICEA S-95-658/NEMA WC70 • UL Listed VW-1 and PR1 COND. STRAND NOMINAL COND. DIAMETER MINIMUM AVG. INSULATION THICKNESS NOMINAL CABLE O.D. COPPER WEIGHT INCHES mm INCHES mm INCHES mm 14 AWG - 1000 kcmil CONDUCTORS 1000 FT kg/km 1000 FT kg/km 60°C 75°C 90°C 14 7W 0.07 1.78 0.045 1.14 0.17 4.32 13 19 24 36 15 15 15 12 7W 0.09 2.29 0.045 1.14 0.19 4.83 20 30 33 49 20 20 20 10 7W 0.12 3.05 0.045 1.14 0.21 5.33 32 48 48 71 30 30 30 8 7W 0.15 3.81 0.060 1.52 0.27 6.86 50 75 78 116 40 50 55 6 7W 0.18 4.57 0.060 1.52 0.31 7.87 81 121 114 170 55 65 75 4 7W 0.23 5.84 0.060 1.52 0.36 9.14 129 192 169 252 70 85 95 2 7W 0.29 7.37 0.060 1.52 0.42 10.67 205 305 254 378 95 115 130 1/0 19W 0.37 9.40 0.080 2.03 0.53 13.46 326 485 403 600 125 150 170 2/0 19W 0.41 10.41 0.080 2.03 0.58 14.73 411 612 501 746 145 175 195 4/0 19W 0.52 13.21 0.080 2.03 0.69 17.53 653 972 760 1131 195 230 260 250 37W 0.56 14.22 0.095 2.41 0.77 19.56 772 1149 906 1349 215 255 290 350 37W 0.67 17.02 0.095 2.41 0.87 22.10 1081 1609 1237 1841 260 310 350 500 37W 0.80 20.32 0.095 2.41 1.00 25.40 1542 2295 1730 2575 320 380 430 750 61W 0.97 24.62 0.110 2.79 1.22 30.99 2316 3447 2576 3834 400 475 535 1000 61W 1.13 28.70 0.110 2.79 1.37 34.80 3086 4593 3405 5068 445 545 615 Dimensions and weights are nominal; subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. † Not available with VW-1 rating. (1) Allowable ampacities shown are for general use as specified by the National Electric Code, 2011 Edition, section 310.15(B)(16). Adjustments and corrections may apply: 60°C – When terminated to equipment for circuits rated 100 amperes or less or marked for 14 through 1 AWG conductors. 75°C – When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than 1 AWG. 90°C – Wet or dry locations. For ampacity derating purposes. Dwelling – For dwelling units, conductors shall be permitted as listed ampacities at 120/240-volt, 3-wire, single-phase services and feeders. Going Green with General Cable General Cable has accelerated its environmental commitment, addressing its green alternative approach by identifying greener opportunities and promoting green cabling solutions wherever feasible. This includes promoting our existing green products, partnering with key customers in their green endeavors, identifying and providing for green product gaps, and participating as a member of the United States Green Building Council (USGBC) and collaborative ventures such as the Green Suppliers Network (GSN). LBS/ NET WEIGHT LBS/ AMPACITY (1) Compliances (cont’d.): Flame Test Compliances: • For 1/0 AWG and larger: IEEE 383 • IEEE 1202/CSA FT4 and FT1 • UL 1685 • UL 44 VW-1 Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP • OSHA Acceptable • RoHS Compliant • NFPA 130 (1/0 & larger sizes) • NES 713 Packaging: • Material cut to length and shipped on non-returnable wood reels Phone: 888-593-3355 www.generalcable.com