SPEC 6160 September, 2016 Aluminum Uniblend PVC High Speed ® EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 5 kV and 8 kV, UL Type MV-105, 133%/100% Ins. Levels, 115 Mils Product Construction: Conductor: • 6 AWG thru 1000 kcmil 1350 aluminum compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • 5 mil annealed copper tape with an overlap of 25% Jacket: • Low-friction, lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) Options: • STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications CATALOG NUMBER 17001.120608* 17001.120408* 17001.120208* 17001.120108* 17001.125108* 17001.125208* (AWG/ kcmil) 6 4 2 1 1/0 2/0 17001.125308* 3/0 17001.135408* 4/0 17001.136008* 250 17001.136208* 350 17001.136508* 500 17001.137008* 750 17001.137508* 1000 COND. SIZE CONDUCTOR DIAMETER INCHES 0.17 0.22 0.27 0.31 NOMINAL INSULATION DIAMETER INCHES THICKNESS NOMINAL JACKET Applications (cont'd.): • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • High Speed low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions NOMINAL CABLE DIAMETER WEIGHT ALUMINUM WEIGHT COPPER WEIGHT CONDUIT IN AIR (1) Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing AMPACITY UNDERGROUND DUCT (2) MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km 90˚C 105˚C 90˚C 5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS 0.415 0.490 0.060 1.52 0.65 16.51 0.455 0.535 0.060 1.52 0.70 17.15 0.510 0.590 0.060 1.52 0.76 19.05 0.545 0.620 0.060 1.52 0.79 20.07 0.34 0.580 0.655 0.060 1.52 0.82 21.08 0.38 0.620 0.695 0.060 1.52 0.86 22.10 0.43 0.665 0.745 0.080 2.03 0.94 24.38 0.48 0.53 0.62 0.74 0.91 1.06 1.320 1.400 0.080 2.03 1.60 42.42 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions. 0.720 0.795 0.080 2.03 1.00 25.65 0.770 0.850 0.080 2.03 1.05 27.18 0.870 0.945 0.080 2.03 1.14 29.72 0.990 1.065 0.080 2.03 1.27 33.53 1.170 1.250 0.080 2.03 1.45 38.35 239 275 328 359 396 442 526 599 661 807 1012 1349 1664 356 409 488 534 590 658 783 891 984 1201 1506 2008 2476 25 39 62 78 99 125 158 199 234 329 468 703 937 37 58 92 116 147 186 235 296 348 490 696 1046 45 49 54 57 60 63 67 72 77 84 95 111 1394 122 67 73 65 72 84 94 70 91 TRAY (3) 105˚C 90˚C 105˚C 75 98 81 115 130 120 130 84 130 150 135 90 150 170 155 94 175 200 175 100 200 225 200 107 230 260 230 115 255 290 250 125 310 350 305 141 385 430 370 165 485 540 455 182 565 640 525 145 - - - - - - - - 165 150 170 190 175 195 215 205 225 245 235 265 270 260 290 330 325 360 400 400 450 490 525 585 565 630 705 SIZING (4) (INCHES) 2 2.5 2.5 2.5 3 3 3 3 3.5 3.5 4 5 5 CONDUIT Phone: 888-593-3355 www.generalcable.com