SPEC 8350 September, 2016 HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 5 kV (133% Ins. Level)/8 kV (100% Ins. Level), 115 Mils, CSA HVTECK, Three Conductor Product Construction: Conductor: • 4 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • A semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 Compliances (cont'd.): Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) • ICEA T-29-520 (210,000 BTU/hr) Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NOMINAL DIAMETER (OVER) CATALOG NUMBER COND. NO. OF (AWG/ kcmil) 17496.750400* 3 4 17496.750200* 3 2 17496.750100* 3 1 COND. SIZE GROUND WIRE SIZE INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km COPPER WEIGHT NET WEIGHT W/ARMOR LBS/1000 FT 4 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 5 kV 133% / 8 kV 100% INS. LEVEL, 115 MILS INS. (2.92 mm) (TO AEIC) 8 0.48 12.3 0.55 13.9 1.37 34.8 1.65 41.9 1.75 44.5 505 752 1500 2040 2230 3040 122 6 0.54 13.7 0.61 15.5 1.50 38.2 1.78 45.2 1.88 47.8 774 1152 1930 2630 2870 3910 141 6 0.57 14.5 0.64 16.3 1.57 39.9 1.86 47.3 1.96 49.8 943 1403 2150 2880 3200 2490 161 17496.755100* 3 1/0 6 0.61 15.4 0.68 17.3 1.65 41.9 1.94 49.3 2.04 51.8 1151 1713 2430 3200 3620 4760 184 17496.755200* 3 2/0 6 0.65 16.4 0.72 18.3 1.80 45.6 2.09 53.1 2.19 55.7 1417 2109 2890 3720 4300 5540 212 17496.755300* 3 3/0 4 0.70 17.7 0.76 19.3 1.90 48.3 2.19 55.7 2.29 58.2 1796 2673 3360 4240 5000 6310 242 17496.755400* 3 4/0 4 0.75 18.9 0.81 20.6 2.01 51.0 2.30 58.5 2.43 61.8 2215 3296 3940 4870 5860 7240 278 17496.756000* 3 250 4 0.80 20.3 0.87 22.1 2.13 54.1 2.42 61.5 2.55 64.8 2583 3844 4470 5450 6650 8120 306 17496.756200* 3 350 3 0.94 23.9 1.01 25.7 2.43 61.8 2.72 69.1 2.85 72.4 3572 5316 5650 6730 8400 10020 373 17496.756500* 3 500 3 1.02 26.0 1.11 28.2 2.64 67.1 2.93 74.5 3.06 77.8 5004 7447 7440 8660 11070 12880 450 17496.757000* 3 750 2 1.20 30.6 1.29 32.8 3.10 78.8 3.39 86.1 3.54 89.9 7431 11059 10560 11980 15710 17830 545 17496.757500* 3 1000 1 1.35 34.3 1.44 36.6 3.42 86.9 3.71 94.3 3.86 98.1 9863 14678 13300 14870 19790 22130 640 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). Ampacity based on CE Code Table D17N and Rule 4-004. kg/km AL STEEL AL STEEL AMPACITY** (40˚C AMBIENT) OUTDOOR Phone: 888-593-3355 www.generalcable.com 4/2017
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait