SPEC 7250 September, 2016 Duralox Uniblend ® Conductors: • 6 AWG thru 1000 kcmil bare, copper compact Class B strand Extruded Strand Shield (ESS): • Thermoset semi-conducting extruded stress control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Shield: • 5 mil annealed copper tape with a minimum 25% overlap Ground: • Annealed bare copper Class B stranding per ASTM B8 Armor: • Aluminum Interlocked Armor (AIA) Jacket: • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), yellow Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, maximum performance is demanded, space is limited, ease of installation is critical and fire resistance is necessary CATALOG NUMBER 17473.530600* 17473.530400* 17473.530200 17473.535100* 17473.535200 17473.535400 17473.536000* 17473.536200 17473.536500 17473.537000* 17473.537500* COND. (AWG) INCHES INCHES mm INCHES mm (AWG) INCHES mm INCHES mm INCHES mm 6 AWG - 1000 kcmil CONDUCTORS NO. OF COND. SIZE COND. DIA. MIN. Applications (cont'd.): • Installed in wet or dry locations, indoors or outdoors, direct burial and in exposed or concealed work • May be used in cable trays or on approved support in protected areas • Permitted for use per NEC Article 330 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2 Features: • Rated at 105˚C wet or dry • Excellent heat and moisture resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical- and radiation-resistant • Excellent crush resistance • Cost-effective alternative to installations in conduit • Meets cold bend test at -40˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions • Sunlight-resistant for CT use INSULATION DIAMETER GRND. WIRE SIZE MAX. NOM. DIA. (OVER) ARMOR THICKNESS NOMINAL JACKET Compliances: Industry Compliances: • UL 1072 • ICEA S-93-639/NEMA WC74 • AEIC CS8 • UL Type MV-105, UL File # E90501 • UL Type MC, UL File # E90496 Flame Test Compliances: • IEEE 383 (70,000 BTU/hr) • UL 1685 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-29-520 (210,000 BTU/hr) • ICEA T-30-520 (70,000 BTU/hr) Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing ® EPR/AIA/PVC, Power, Shielded, Armored 5 kV/8 kV, UL Type MV-105 or MC, 133%/100% Ins. Levels, 115 Mils, Three Conductor Product Construction: NOMINAL CABLE O.D. 5 kV, 133% INS. LEVEL OR 8 kV, 100% INS. LEVEL, 115 MILS INS. 3 6 0.17 0.42 10.5 0.49 12.5 6 1.33 33.8 0.050 1.27 1.44 36.6 462 688 1133 1687 3 4 0.21 0.46 11.6 0.54 13.7 6 1.43 36.2 0.050 1.27 1.54 39.1 619 922 1354 2016 3 2 0.27 0.51 13.0 0.59 14.9 6 1.64 41.6 0.060 1.52 1.77 44.9 864 1286 1819 2708 3 1/0 0.34 0.58 14.7 0.66 16.7 4 1.79 45.3 0.060 1.52 1.92 48.6 1298 1933 2364 3520 3 2/0 0.38 0.62 15.7 0.70 17.7 4 1.87 47.5 0.060 1.52 2.00 50.8 1566 2332 2696 4014 3 4/0 0.48 0.72 18.3 0.80 20.3 3 2.09 53.2 0.060 1.52 2.22 56.5 2360 3514 3687 5490 3 250 0.52 0.77 19.6 0.85 21.5 2 2.21 56.0 0.060 1.52 2.34 59.3 2735 4072 4165 6202 3 350 0.62 0.87 22.1 0.95 24.1 2 2.41 61.3 0.075 1.91 2.57 65.4 3736 5563 5436 8094 3 500 0.74 0.99 25.1 1.07 27.1 1 2.64 67.0 0.075 1.91 2.84 72.0 5222 7776 7170 10676 3 750 0.91 1.17 29.7 1.25 31.8 1/0 3.06 77.8 0.085 2.16 3.25 82.4 7684 11441 10084 15015 3 1000 1.07 1.33 33.8 1.40 35.6 2/0 3.39 86.1 0.085 2.16 3.57 90.8 10057 14975 12793 19049 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. COPPER WEIGHT 1000 FT LBS/ kg/ km NET WEIGHT W/AL ARMOR 1000 FT LBS/ kg/ km Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait