SPEC 8075 September, 2016 TECK90 XLPE/PVC/AIA/PVC, Control, Armored 600 V, CSA TECK90, Multi-Conductor, 10 AWG Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Product Construction: Conductor: • 10 AWG bare copper Class B compressed concentric round to ASTM B8 Insulation: • Cross-linked Polyethylene (XLPE), Type RW90 • Color-coded: 1 to 4 conductors —black, white, red and blue; over 4 conductors—per ICEA Method 4, individual conductors colored black with conductor number surface printed in contrasting ink Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor • Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing CATALOG NUMBER 780200 780230 780270 319480* 333160* 346870* 318740* 311570* 317890* 318750* 308180* 307450* 293570* 307460* 346900* COND. 2 3 4 5 6 7 8 10 12 15 20 25 30 40 50 NO. OF (AWG) 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 COND. SIZE GROUND WIRE SIZE (AWG) INSULATION NOMINAL DIAMETER (OVER) ARMOR COPPER WEIGHT CABLE INCHES mm INCHES mm INCHES mm 12 0.18 4.5 17.0 0.75 19.0 1000 FT LBS/ kg/ km 87 130 AL NET WEIGHT W/ARMOR LBS/1000 FT STEEL 10 AWG—MULTI-CONDUCTOR—30 MILS INS. (.76 mm), 600 V 0.67 12 0.18 4.5 0.70 17.7 0.78 19.7 119 177 12 0.18 4.5 0.74 18.8 0.83 20.9 150 223 12 0.18 4.5 0.82 20.9 0.91 22.9 184 274 12 0.18 4.5 0.88 22.2 0.96 24.3 217 323 12 0.18 4.5 0.90 22.9 0.99 25.0 248 369 12 0.18 4.5 0.93 23.6 1.02 25.7 282 420 12 0.18 4.5 1.08 27.3 1.16 29.4 348 518 12 0.18 4.5 1.15 29.2 1.23 31.3 414 617 AL kg/km STEEL 275 411 410 612 327 470 487 700 413 565 615 841 473 644 704 959 515 717 766 1066 552 754 821 1122 613 830 912 1235 828 1181 1232 1757 916 1276 1363 1899 12 0.18 4.5 1.22 30.9 1.30 33.0 512 762 1084 1481 1613 2203 12 0.18 4.5 1.36 34.4 1.44 36.5 675 1005 1316 1750 1958 2604 12 0.18 4.5 1.47 37.3 1.55 39.4 835 1243 1612 2099 2399 3124 12 0.18 4.5 1.55 39.4 1.65 41.8 998 1493 1821 2323 2709 3457 12 0.18 4.5 1.71 43.4 1.81 45.9 1321 1966 2278 2837 3390 4222 12 0.18 4.5 1.87 47.5 1.97 49.9 1648 2453 2820 3557 4196 5293 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacity is based on CE Code Part 1, Table 2 for 3 conductors in raceway (conduit). Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral. Ampacity at 5 or more conductors is modified by Table 5C. AMPACITY** (30˚C AMBIENT) 40 40 40 32 32 28 28 28 28 28 28 24 24 24 20 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait