SPEC 8100 September, 2016 TECK90 XLPE/PVC/AIA/PVC, Power, Armored 1000 V, CSA TECK90, Single Conductor Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Insulation: • Cross-linked Polyethylene (XLPE), Type RW90 • Color-coded: black Ground (Bonding) Conductor: • The conductor is a concentric serving of solid bare copper wires applied over the insulation Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations Applications (cont'd.): • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) CATALOG NUMBER 11288.040600* 11288.050400* 11288.030300* 11288.050200* 11288.050100* 11288.035100* 11288.035200* 11288.035300* 11288.025400* 11288.026000* 11288.036200* 11288.026500* 11288.027000* 11288.027500* COND. 1 1 1 1 1 NO. OF (AWG/ kcmil) 6 4 3 2 1 1 1/0 1 2/0 1 3/0 1 4/0 1 250 1 350 1 500 1 750 COND. SIZE GROUND WIRE SIZE (AWG) 8 6 6 6 4 4 4 3 3 2 1 MIN. AVG. INS. THICKNESS INSULATION NOMINAL DIAMETER (OVER) ARMOR Compliances (cont'd.): Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing COPPER WEIGHT CABLE INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km 6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—1000 V .060 1.52 0.31 7.8 0.68 17.3 0.77 19.6 137 204 .060 1.52 0.35 8.8 0.73 18.6 0.81 20.6 211 314 .060 1.52 0.38 9.8 0.76 19.3 0.84 21.4 244 363 .060 1.52 0.42 10.5 0.78 19.8 0.87 22.1 286 426 .080 2.03 0.49 12.5 0.88 22.4 0.96 24.4 390 581 .080 2.03 0.53 13.5 0.91 23.2 1.00 25.4 458 682 .080 2.03 0.58 14.7 0.95 24.1 1.04 26.4 544 810 LBS/1000 FT kg/km 320 470 410 610 450 680 510 760 680 1010 760 1130 860 1280 1/0 2/0 1 1000 2/0 .080 2.03 0.63 15.9 1.03 26.2 1.12 28.5 685 1020 1080 1610 .080 2.03 0.69 17.5 1.08 27.5 1.17 29.7 820 1220 1270 1890 .090 2.29 0.75 19.2 1.21 30.8 1.29 32.8 980 1459 1490 2210 .090 2.29 0.86 21.7 1.30 33.0 1.39 35.3 1340 1994 1910 2840 .090 2.29 0.99 25.0 1.42 36.1 1.51 38.4 1750 2604 2510 3740 .090 2.29 1.16 29.4 1.59 40.4 1.69 43.0 2570 3825 3510 5230 .090 2.29 1.31 33.2 1.81 46.0 1.90 48.3 3340 4970 4430 6590 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacity is based on CE Code Part 1, Table 1 (single conductor in free air) and Rule 4-004. NET WEIGHT AMPACITY** (30˚C AMBIENT) 105 140 165 190 220 260 300 350 405 455 570 700 885 1055 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait