SPEC 8125 September, 2016 TECK90 XLPE/PVC/AIA/PVC, Control and Power, Armored 1000 V, CSA TECK90, Two Conductor Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) Product Construction: Conductor: • 14 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8 • 6 AWG thru 1000 kcmil bare copper compact Class B strand Insulation: • Cross-linked Polyethylene (XLPE), Type RW90 • Color-coded: 14 AWG to 2 AWG—black and white; 1 AWG to 1000 kcmil—printed numbers Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Meets cold bend and impact tests at -40˚C CATALOG NUMBER 794520* 308550* 793140* 331260* COND. NO. OF (AWG/ kcmil) 2 14 2 12 2 10 2 11206.332083* 2 11288.040400* 2 11288.220300* 2 11288.040200* 2 11288.020100* 2 8 6 4 3 2 1 11288.045100* 2 1/0 11288.045200* 2 2/0 11288.045300* 2 3/0 11288.145400* 2 4/0 11288.226000* 2 250 11288.226200* 2 350 11288.226500* 2 500 11288.227000* 2 750 COND. SIZE GROUND WIRE SIZE (AWG) MIN. AVG. INS. THICKNESS NOMINAL DIAMETER (OVER) INSULATION ARMOR CABLE INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT 14 AWG THRU 1000 kcmil—TWO CONDUCTOR—1000 V 14 .045 1.14 0.17 4.2 0.65 16.5 0.73 18.5 39 14 .045 1.14 0.18 4.6 0.69 17.6 0.77 19.6 55 kg/ km LBS/ Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing COPPER WEIGHT LBS/1000 FT NET WEIGHT W/ARMOR kg/km AL STEEL AL STEEL 58 219 350 326 521 82 255 412 380 613 AMPACITY** (30˚C AMBIENT) 12 .045 1.14 0.21 5.3 0.73 18.5 0.81 20.6 86 128 291 441 433 657 10 .045 1.14 0.24 6.1 0.82 20.8 0.90 22.9 137 204 392 564 584 840 8 .060 1.52 0.31 7.8 0.94 23.9 1.02 25.9 215 320 556 758 827 1128 8 .060 1.52 0.35 8.8 1.07 27.2 1.16 29.5 312 464 744 1052 1107 1565 6 .060 1.52 0.38 9.8 1.15 29.2 1.23 31.3 415 618 905 1239 1347 1844 115 6 .060 1.52 0.42 10.5 1.20 30.5 1.28 32.5 502 747 1030 1380 1533 2054 130 6 .080 2.03 0.49 12.5 1.34 34.0 1.42 36.1 612 911 1235 1630 1838 2425 145 6 .080 2.03 0.53 13.5 1.45 36.8 1.53 38.9 740 1101 1425 1854 2120 2759 170 6 .080 2.03 0.58 14.8 1.50 38.1 1.58 40.1 922 1372 1660 2107 2470 3135 195 4 .080 2.03 0.63 15.9 1.59 40.4 1.69 42.9 1190 1771 1995 2471 2969 3677 225 4 .080 2.03 0.69 17.5 1.70 43.2 1.79 45.5 1466 2182 2350 2862 3497 4259 260 4 .090 2.29 0.75 19.2 1.84 46.8 1.93 49.0 1709 2543 2779 3332 4135 4958 290 3 .090 2.29 0.86 21.7 2.09 53.1 2.18 55.4 2373 3561 3650 4285 5431 6376 350 3 .090 2.29 0.99 25.0 2.33 59.2 2.45 62.2 3316 4935 4895 5607 7284 8343 430 2 .090 2.29 1.16 29.4 2.67 67.8 2.79 70.9 4941 7353 6872 7695 10226 11450 535 11288.227500* 2 1000 1 .090 2.29 1.31 33.2 2.98 75.7 3.10 78.8 6562 9766 8993 10376 13382 15439 615 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004. 25 30 40 55 75 95 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait