SPEC 8150 September, 2016 TECK90 XLPE/PVC/AIA/PVC, Control and Power, Armored 1000 V, CSA TECK90, Three Conductor Product Construction: Conductor: • 14 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8 • 6 AWG thru 1000 kcmil bare copper compact Class B strand Insulation: • Cross-linked Polyethylene (XLPE), Type RW90 • Color-coded: 14 AWG to 2 AWG—black, red and blue; 1 AWG to 1000 kcmil—printed numbers Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations CATALOG NUMBER 330520* 780260 331120 793200 11288.010600 11288.010400 11288.010300 11288.010200 11288.010100 11288.015100 11288.015200 11288.015300 11288.015400 11288.016000 11288.016200 11288.016500 11270.891327 11288.017500* COND. NO. OF (AWG/ kcmil) 3 14 3 12 3 10 3 3 3 3 3 3 8 6 4 3 2 1 COND. SIZE GROUND WIRE SIZE (AWG) MIN. AVG. INS. THICKNESS Applications (cont'd.): • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Features: • Rated at 90˚C wet or dry • Excellent crush resistance, oil and chemical resistance • Provides long service life • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) NOMINAL DIAMETER (OVER) INSULATION ARMOR CABLE INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km 14 AWG THRU 1000 kcmil—THREE CONDUCTOR—1000 V 14 .045 1.14 0.17 4.2 0.67 17.0 0.76 19.3 52 Compliances (cont'd.): Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing COPPER WEIGHT LBS/1000 FT NET WEIGHT W/ARMOR kg/km AL STEEL AL STEEL 77 261 398 388 592 AMPACITY** (30˚C AMBIENT) 14 .045 1.14 0.18 4.6 0.72 18.3 0.80 20.3 75 112 299 445 445 662 12 .045 1.14 0.21 5.3 0.79 20.1 0.88 22.4 124 185 374 539 557 802 10 .045 1.14 0.24 6.1 0.86 21.9 0.94 23.9 189 281 486 666 723 991 8 .060 1.52 0.31 7.8 1.03 26.2 1.13 28.7 300 447 724 836 1078 1244 8 .060 1.52 0.35 8.8 1.16 29.5 1.25 31.8 447 665 970 1327 1444 1975 6 .060 1.52 0.38 9.8 1.22 31.0 1.30 33.0 582 866 1136 1509 1691 2246 115 6 .060 1.52 0.42 10.5 1.28 32.5 1.37 34.8 710 1056 1311 1702 1951 2533 130 6 .080 2.03 0.49 12.5 1.44 36.6 1.54 39.1 866 1288 1593 2045 2371 3043 145 6 .080 2.03 0.53 13.5 1.56 39.6 1.68 42.7 1069 1590 1906 2389 2837 3555 170 6 .080 2.03 0.58 14.8 1.65 41.9 1.77 45.0 1327 1974 2225 2732 3311 4066 195 4 .080 2.03 0.63 15.9 1.75 44.5 1.87 47.5 1670 2485 2666 3261 3967 4853 225 4 .080 2.03 0.69 17.5 1.86 47.2 1.98 50.3 2109 3138 3207 3806 4772 5664 260 4 .090 2.29 0.75 19.2 2.05 52.1 2.17 55.1 2470 3675 3800 4513 5655 6716 290 3 .090 2.29 0.86 21.7 2.26 57.4 2.40 61.0 3437 5114 4979 5906 7409 8789 350 3 .090 2.29 0.99 25.0 2.52 64.0 2.66 67.6 4839 7200 6586 7627 9798 11349 430 2 .090 2.29 1.16 29.4 2.89 73.4 3.03 77.0 7225 10751 9267 10470 13790 15580 535 3 1000 1 .090 2.29 1.31 33.2 3.28 83.3 3.44 87.4 9612 14303 12184 13566 18130 20187 615 3 1/0 3 2/0 3 3/0 3 4/0 3 250 3 350 3 500 3 750 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004. 25 30 40 55 75 95 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait