SPEC 8175 September, 2016 TECK90 XLPE/PVC/AIA/PVC, Control and Power, Armored 1000 V, CSA TECK90, Four Conductor Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) Product Construction: Conductor: • 14 AWG thru 8 AWG bare copper Class B compressed concentric round to ASTM B8 • 6 AWG thru 1000 kcmil bare copper compact Class B strand Insulation: • Cross-linked Polyethylene (XLPE), Type RW90 • Color-coded: 14 AWG to 2 AWG—black, red, blue and white; 1 AWG to 1000 kcmil—printed numbers Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Meets cold bend and impact tests at -40˚C CATALOG NUMBER 321940* 793180* 793160* 331250 11288.030600 11288.020400 11288.020300 11288.020200 11288.040100 11288.025100 11288.025200 11288.025300 11288.045400 11288.046000 11288.026200 COND. NO. OF (AWG/ kcmil) 4 14 4 12 4 10 4 4 4 4 4 4 8 6 4 3 2 1 4 1/0 4 2/0 4 3/0 4 4/0 4 250 4 350 11288.036500* 4 500 11288.057000* 4 750 COND. SIZE GROUND WIRE SIZE (AWG) MIN. AVG. INS. THICKNESS NOMINAL DIAMETER (OVER) INSULATION ARMOR CABLE INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km 14 AWG THRU 1000 kcmil—FOUR CONDUCTOR—1000 V 14 .045 1.14 0.17 4.2 0.72 18.3 0.80 20.3 68 101 290 440 430 660 14 .045 1.14 0.18 4.6 0.79 20.1 0.88 22.4 96 143 357 521 531 776 12 .045 1.14 0.21 5.3 0.85 21.6 0.93 23.6 150 223 455 632 677 941 10 .045 1.14 0.24 6.1 0.92 23.4 1.00 25.4 241 359 548 736 816 1096 8 .060 1.52 0.31 7.8 1.15 29.2 1.25 31.8 383 570 907 1261 1350 1877 8 .060 1.52 0.35 8.8 1.26 32.0 1.35 34.3 579 862 1168 1558 1738 2319 6 .060 1.52 0.38 9.8 1.31 33.3 1.40 35.6 748 1113 1373 1782 2043 2652 115 6 .060 1.52 0.42 10.5 1.37 34.8 1.46 37.1 919 1368 1583 2013 2356 2996 130 6 .080 2.03 0.49 12.5 1.60 40.6 1.72 43.7 1128 1679 2032 2551 3024 3796 145 6 .080 2.03 0.53 13.5 1.69 42.9 1.81 46.0 1398 2081 2365 2914 3520 4336 170 6 .080 2.03 0.58 14.8 1.79 45.5 1.91 48.5 1742 2593 2745 3331 4085 4957 195 4 .080 2.03 0.63 15.9 1.91 48.5 2.03 51.6 2223 3308 3398 4135 5057 6153 225 4 .080 2.03 0.69 17.5 2.09 53.1 2.21 56.1 2769 4121 4170 4983 6205 7415 260 4 .090 2.29 0.75 19.2 2.23 56.7 2.35 59.7 3249 4835 4789 5661 7126 8424 290 3 .090 2.29 0.86 21.7 2.46 62.5 2.60 66.0 4528 6738 6307 7264 9385 10809 350 3 .090 2.29 0.99 25.0 2.76 70.1 2.90 73.7 6395 9516 8438 9515 12556 14159 430 2 .090 2.29 1.16 29.4 3.24 82.3 3.42 86.9 9564 14232 12411 13683 18468 20360 535 11288.037500* 4 1000 1 .090 2.29 1.31 33.2 3.65 92.7 3.84 97.6 12885 19173 15800 23510 23500 34968 615 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacity is based on CE Code Part 1, Table 2 (Three conductors in raceway [conduit]) and Rule 4-004. Ampacity of 4 conductor cable is based on 3 current-carrying conductors and 1 neutral. 25 30 40 55 75 95 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing COPPER WEIGHT LBS/1000 FT NET WEIGHT W/ARMOR kg/km AL STEEL AL STEEL AMPACITY** (30˚C AMBIENT) Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait