SPEC 6560 September, 2016 Aluminum Uniblend PVC High Speed ® EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils Product Construction: Conductor: • 1/0 AWG thru 1000 kcmil 1350 aluminum compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • 5 mil annealed copper tape with an overlap of 25% Jacket: • Low-friction, lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) Options: • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications Applications (cont’d.): • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • High Speed low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions CATALOG NUMBER (AWG/ kcmil) 17061.135108* 1/0 17061.135208* 2/0 17061.135308* 3/0 17061.135408 4/0 17061.136008* 250 17061.136208 350 17061.136508 500 17061.137008 750 17061.137508 1000 COND. SIZE CONDUCTOR DIAMETER INCHES 0.34 0.38 0.43 0.48 0.53 0.62 0.74 0.91 NOMINAL INSULATION DIAMETER INCHES THICKNESS NOMINAL JACKET NOMINAL CABLE DIAMETER & 35 kV¥¥ WEIGHT ALUMINUM WEIGHT COPPER WEIGHT 1.020 1.120 0.080 2.03 1.31 33.27 1.060 1.160 0.080 2.03 1.35 34.29 1.105 1.205 0.080 2.03 1.40 35.56 1.160 1.260 0.080 2.03 1.45 36.83 1.210 1.315 0.080 2.03 1.51 38.35 1.310 1.410 0.080 2.03 1.60 40.64 1.430 1.530 0.080 2.03 1.72 45.21 1.610 1.710 0.110 2.79 1.96 49.78 1.06 1.760 1.865 0.110 2.79 2.10 53.59 , UL TYPE MV-105, 133%/100% INS. LEVEL, 345 MILS 863 1285 925 1000 1093 1174 1356 1707 2120 2500 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. ¥ 100% insulation level is available upon request. ¥¥ 133% insulation level is available upon request. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions. 99 1377 125 1488 1626 1747 2018 2540 3155 158 199 234 329 468 703 3720 937 147 186 235 296 348 490 696 1046 1394 99 103 107 112 116 125 135 151 162 CONDUIT IN AIR (1) Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 • UL 1685 UL Flame Exposure Test • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing AMPACITY UNDERGROUND DUCT (2) MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km 90˚C 105˚C 90˚C 25 kV¥ 147 150 170 153 175 200 159 200 225 167 230 260 173 255 290 155 175 200 230 250 186 310 350 305 201 385 430 225 485 540 241 565 640 370 455 525 TRAY (3) 105˚C 90˚C 105˚C 165 190 215 245 270 330 150 170 175 195 205 225 235 260 260 285 325 355 400 400 445 490 565 515 575 620 690 SIZING (4) (INCHES) 5 5 5 5 5 5 6 6 8 CONDUIT Phone: 888-593-3355 www.generalcable.com