SPEC 6575 September, 2016 Uniblend CPE High Speed ® EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded 25 kV and 35 kV, UL Type MV-105, 133%/100% Ins. Levels, 345 Mils Features (cont’d.): • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Product Construction: Conductor: • 1/0 AWG thru 1000 kcmil annealed bare copper compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • 5 mil annealed copper tape with an overlap of 25% Jacket: • Flame-retardant, moisture- and sunlight-resistant Chlorinated Polyethylene (CPE) Options: • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610 CATALOG NUMBER 17161.135105 17161.135205* 17161.135305* 17161.135405 (AWG/ kcmil) 1/0 2/0 3/0 4/0 17161.136005* 250 17161.136205 17161.136505 17161.137005 350 500 750 17161.137505* 1000 COND. SIZE CONDUCTOR DIAMETER INCHES 0.34 0.38 0.43 0.48 0.53 0.63 0.74 0.91 NOMINAL INSULATION DIAMETER INCHES NOMINAL CABLE NOMINAL JACKET THICKNESS & 35 kV¥¥ DIAMETER WEIGHT COPPER WEIGHT CONDUIT IN AIR (1) 1.020 1.120 0.080 2.03 1.060 1.160 0.080 2.03 1.105 1.205 0.080 2.03 1.160 1.260 0.080 2.03 1.210 1.315 0.080 2.03 1.310 1.410 0.080 2.03 1.430 1.530 0.080 2.03 1.610 1.710 0.110 2.79 1.06 1.760 1.865 0.110 2.79 , UL TYPE MV-105, 133%/100% INS. LEVEL, 345 MILS 1.31 33.27 1.35 34.29 1.40 35.56 1.45 36.83 1.51 38.35 1.60 40.64 1.72 45.21 1.96 49.78 2.10 53.59 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. ¥ 100% insulation level is available upon request. ¥¥ 133% insulation level is available upon request. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions. 1066 1187 1335 1516 1681 2075 2650 3687 4603 1586 1766 1986 2256 2501 3088 3934 5486 6849 425 514 625 765 888 1206 1679 2467 3250 AMPACITY UNDERGROUND DUCT (2) MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km 90˚C 105˚C 90˚C 25 kV¥ 633 195 215 765 225 255 930 260 290 1138 295 330 1322 330 365 200 230 260 295 325 1794 395 440 390 2498 480 535 3670 585 655 4836 675 755 465 565 640 TRAY (3) 105˚C 90˚C 105˚C 215 245 275 315 195 220 225 250 260 285 295 335 345 330 370 415 410 455 500 610 690 510 565 655 730 780 870 SIZING (4) (INCHES) 5 5 5 5 5 5 6 6 8 CONDUIT Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • Excellent flame resistance – burns to an ash; does not exhibit thermoplastic drip • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High Speed low friction technology for easy cable pulling • High dielectric strength Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing Phone: 888-593-3355 www.generalcable.com 3/2017