SPEC 6660 September, 2016 Aluminum Uniblend PVC High Speed ® EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 35 kV, UL Type MV-105, 133% Ins. Levels, 420 Mils Product Construction: Conductor: • 1/0 AWG thru 1000 kcmil 1350 aluminum compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • 5 mil annealed copper tape with an overlap of 25% Jacket: • Low-friction, lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) Options: • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • High Speed low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance CATALOG NUMBER (AWG/ kcmil) 17071.135108* 1/0 17071.135208* 2/0 17071.135308* 3/0 17071.135408* 4/0 17071.136008* 250 17071.136208* 350 17071.136508* 500 17071.137008* 750 17071.137508* 1000 COND. SIZE CONDUCTOR DIAMETER INCHES 0.34 0.38 0.43 0.48 0.53 0.62 0.74 0.91 NOMINAL INSULATION DIAMETER INCHES THICKNESS NOMINAL JACKET NOMINAL CABLE DIAMETER WEIGHT ALUMINUM WEIGHT COPPER WEIGHT CONDUIT IN AIR (1) Features (cont’d.): • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing AMPACITY UNDERGROUND DUCT (2) MIN. MAX. INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km LBS/1000 FT kg/km 90˚C 105˚C 90˚C 35 kV, UL TYPE MV-105, 133% INS. LEVEL, 420 MILS 1.060 1.265 0.080 2.03 1.47 37.34 1.200 1.305 0.080 2.03 1.49 37.85 1.245 1.355 0.080 2.03 1.53 38.86 1.300 1.405 0.080 2.03 1.59 40.39 1.350 1.460 0.080 2.03 1.64 41.66 1.450 1.555 0.110 2.79 1.79 45.47 1.570 1.675 0.110 2.79 1.91 48.50 1.750 1.860 0.110 2.79 2.09 53.09 1.06 1.900 2.010 0.110 2.79 2.25 57.15 1026 1092 1172 1262 1350 1644 1910 2341 2734 1527 1625 1744 1878 2009 2447 2842 3484 4069 99 125 158 199 234 329 468 703 937 147 186 235 296 348 490 696 1046 1394 111 114 118 123 127 136 146 161 175 165 150 170 170 175 200 175 200 225 183 230 260 189 255 290 155 175 200 230 250 202 310 350 305 217 385 430 240 485 540 260 565 640 370 455 525 TRAY (3) 105˚C 90˚C 105˚C 165 190 215 245 270 330 150 170 175 195 205 225 235 260 260 285 325 355 400 400 445 490 565 515 575 620 690 SIZING (4) (INCHES) 5 5 5 6 6 6 6 8 8 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. Note: a) All sizes are “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions. CONDUIT Phone: 888-593-3355 www.generalcable.com