SPEC 7100 September, 2016 Duralox ® XLPE/AIA/PVC, Power, Armored 600 V, UL Type MC, Three and Four Conductor (8 AWG—4/0 AWG) Product Construction: Conductors: • 8 AWG bare compressed copper, Class B stranding per ASTM B8 • 6 AWG thru 4/0 AWG bare compact copper, Class B stranding per ASTM B496 Insulation: • Cross-linked Polyethylene (XLPE) • Color-coded per ICEA Method 3, Table E-2 Ground: • Annealed bare copper Class B stranding per ASTM B8 Armor: • Aluminum Interlocked Armor (AIA) Jacket: • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • Ideally suited for use in a broad range of commercial, industrial and utility applications, where maximum performance is demanded, ease of installation desired and fire resistance is critical • Permitted for use per NEC Article 330 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2 CATALOG NUMBER 346630 346640* 11298.030600 11298.040600* 11298.030400 11298.040400* 11298.030200 11298.040200* 11298.030100* 11298.040100* 11298.035100 11298.045100* 11298.035200 11298.045200* 11298.035300 11298.045300* 11298.035400 11298.045400* COND. 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 NO. OF (AWG) 8 8 6 6 4 4 2 2 1 1 1/0 1/0 2/0 2/0 3/0 3/0 4/0 4/0 COND. SIZE GRND. WIRE SIZE (AWG) Applications (cont’d.): • Installed in both exposed or concealed work, wet or dry locations, indoors or outdoors, direct burial and cable trays Features: • Rated at 90˚C wet or dry • Provides excellent oil and chemical resistance • Excellent crush resistance • Provides a long service life • Cost-effective alternative to installations in conduit • Meets cold bend test at -40˚C • Sunlight-resistant for CT use Compliances: Industry Compliances: • UL 1569 • UL 44 • ICEA S-95-658/NEMA WC70 • UL Type MC-600 volts, UL File # E90496 • NEC Type XHHW-2 conductors Compliances (cont’d.): Flame Test Compliances: • IEEE 383 (70,000 BTU/hr) • UL 1685 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-29-520 (210,000 BTU/hr) Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing INSULATION THICKNESS MINIMUM NOM. DIA. (OVER) ARMOR 10 0.045 1.14 0.74 10 0.045 1.14 0.80 8 0.045 1.14 8 0.045 1.14 8 0.045 1.14 8 0.045 1.14 6 0.045 1.14 6 0.045 1.14 6 0.055 1.40 6 0.055 1.40 6 0.055 1.40 6 0.055 1.40 6 0.055 1.40 6 0.055 1.40 4 0.055 1.40 4 0.055 1.40 4 0.055 1.40 4 0.055 1.40 THICKNESS 0.79 0.86 0.89 0.97 1.00 1.10 1.12 18.8 0.050 1.27 20.3 0.050 1.27 20.1 21.8 22.5 NOMINAL JACKET NOMINAL CABLE O.D. 0.050 1.27 0.050 1.27 0.050 1.27 24.6 0.050 1.27 25.5 27.9 28.4 1.23 31.2 1.20 1.32 1.29 1.42 1.39 1.54 1.50 1.75 30.5 33.5 32.8 36.1 0.050 1.27 0.050 1.27 0.050 1.27 0.050 1.27 0.050 1.27 0.050 1.27 0.050 1.27 0.050 1.27 35.4 0.050 1.27 39.0 38.2 0.060 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. 0.060 1.52 44.4 0.060 1.52 0.84 0.90 0.90 0.97 1.00 1.08 1.11 1.21 21.4 22.9 22.9 24.6 25.3 27.4 28.3 30.7 1.23 31.2 1.34 1.31 1.43 1.40 1.53 1.50 1.52 1.67 1.63 1.88 34.0 33.3 36.3 35.6 38.8 38.2 42.4 41.5 47.7 COPPER WEIGHT 189 241 286 365 434 562 673 869 834 1083 1050 1373 1284 1685 1621 2120 2027 2657 281 359 426 543 646 836 1002 1293 1241 1612 1563 2043 1911 2508 2412 3155 3017 WEIGHT INCHES mm INCHES mm INCHES mm INCHES mm LBS/1000 FT kg/km LBS/1000 FT kg/km 8 AWG - 4/0 AWG CONDUCTORS 420 507 546 659 736 906 1028 1283 1273 1568 1490 1890 1775 2216 2071 2754 2619 3954 3485 625 755 813 980 1096 1349 1530 1909 1894 2334 2217 2812 2642 3298 3082 4098 3898 5187 NET Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait