90 Industrial Cables SPEC 8300 Feb, 2025 Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • Black semi-conducting thermosetting layer, applied in a triple extrusion process, plus a concentric serving of solid copper wires acting as both a drain wire shield and a grounding (bonding) conductor Ground (Bonding) Conductor: • The conductor is a concentric serving of solid copper wires applied over the thermosetting insulation shield Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provide long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing HVTECK TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored 5 kV (133% Ins. Level)/8 kV (100% Ins. Level) 115 Mils, CSA HVTECK, Single Conductor NO. OF COND COND. SIZE (AWG/ kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/AL ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—SHIELDED, 133% INS. LEVEL, 115 MILS INS. (2.92 mm)—5 kV 1 6 8 0.44 11.2 0.51 13.0 0.73 18.6 0.95 24.2 1.04 26.4 145 216 550 820 112 1 4 6 0.48 12.3 0.55 13.9 0.77 19.6 0.99 25.2 1.08 27.5 225 335 680 1010 148 1 2 6 0.54 13.7 0.61 15.5 0.83 21.1 1.08 27.5 1.17 29.7 303 451 840 1250 198 1 1 4 0.57 14.5 0.64 16.3 0.91 23.0 1.16 29.5 1.25 31.8 407 606 960 1430 225 1 1/0 4 0.61 15.4 0.68 17.3 0.94 23.9 1.19 30.3 1.28 32.5 407 606 1060 1570 255 1 2/0 4 0.65 16.4 0.72 18.3 0.98 25.0 1.23 31.3 1.32 33.6 476 708 1170 1740 291 1 3/0 3 0.70 17.7 0.76 19.3 1.03 26.3 1.31 33.3 1.40 35.6 563 838 1350 2000 327 1 4/0 3 0.75 18.9 0.81 20.6 1.08 27.5 1.36 34.6 1.45 36.9 710 1057 1520 2260 373 1 250 2 0.80 20.3 0.87 22.1 1.16 29.6 1.44 36.6 1.53 38.9 849 1263 1730 2580 417 1 350 1 0.94 23.9 1.01 25.7 1.29 32.8 1.57 39.9 1.67 42.4 1169 1740 2170 3230 491 1 500 1/0 1.02 26.0 1.11 28.2 1.41 35.8 1.69 43.0 1.79 45.6 1390 2069 2860 4260 562 1 750 2/0 1.20 30.6 1.29 32.8 1.60 40.7 1.89 48.0 1.99 50.6 2821 4198 3940 5860 642 1 1000 2/0 1.35 34.3 1.44 36.6 1.81 46.0 2.10 53.4 2.20 55.9 3608 5369 5090 7570 740 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). Ampacity based on CE Code Table D17M and Rule 4-004.
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait