91 Industrial Cables SPEC 8325 Feb, 2025 Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • A semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 5 kV CSA HVTECK, 100% Ins. Level, 90 Mils, Three Conductor NO. OF COND. COND. SIZE (AWG/ kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/1000 FT kg/km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm AL STEEL AL STEEL 6 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 100% INS. LEVEL, 90 MILS INS. (2.29 mm)—5 kV 3 6 8 0.39 10.0 0.47 11.9 1.17 29.7 1.45 36.9 1.54 39.2 349 519 1120 1590 1670 2360 93 3 4 8 0.45 11.3 0.51 12.8 1.28 32.6 1.53 38.9 1.65 42.0 447 665 1357 1804 2020 2684 122 3 2 6 0.50 12.8 0.56 14.3 1.41 35.8 1.70 43.1 1.82 46.2 710 1056 1737 2263 2585 3368 141 3 1 6 0.52 13.2 0.60 15.2 1.45 36.8 1.73 43.9 1.83 46.5 939 1397 1960 2486 2916 3699 161 3 1/0 6 0.57 14.4 0.63 16.0 1.55 39.4 1.84 46.7 1.96 49.8 875 1302 2248 2931 3344 4361 184 3 2/0 6 0.61 15.5 0.67 17.0 1.64 41.7 1.93 49.0 2.05 52.1 1340 1994 2563 3284 3814 4886 212 3 3/0 4 0.64 16.3 0.71 18.0 1.78 45.2 2.07 52.6 2.17 55.1 1798 2675 3210 3930 4776 5848 242 3 4/0 4 0.71 18.0 0.77 19.5 1.92 48.7 2.21 56.1 2.33 59.1 2130 3169 3626 4532 5395 6743 278 3 250 4 0.77 19.4 0.83 21.0 2.03 51.5 2.32 58.9 2.46 62.4 2494 3711 4155 5109 6182 7603 306 3 350 3 0.86 21.9 0.92 23.4 2.26 57.4 2.55 64.7 2.69 68.3 3471 5164 5276 6200 7850 9225 373 3 500 3 0.97 24.7 1.03 26.2 2.50 63.4 2.79 70.8 2.93 74.4 4884 7268 6825 7842 10156 11669 450 3 750 2 1.15 29.2 1.24 31.5 2.98 75.7 3.27 83.1 3.42 86.9 7440 11072 10330 11700 15370 17410 545 3 1000 1 1.30 33.0 1.39 35.3 3.31 84.1 3.60 91.5 3.75 95.3 9860 14674 13080 14600 19460 21730 640 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). Ampacity based on CE Code Table D17N and Rule 4-004.
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait