92 Industrial Cables SPEC 8350 Feb, 2025 HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 5 kV (133% Ins. Level)/8 kV (100% Ins. Level) 115 Mils, CSA HVTECK, Three Conductor Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • A semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NO. OF COND. COND. SIZE (AWG/ kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/1000 FT kg/km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm AL STEEL AL STEEL 6 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 133% INS. LEVEL, 115 MILS INS. (2.92 mm)—5 kV 3 6 8 0.44 11.2 0.51 13.0 1.27 32.3 1.55 39.4 1.65 41.9 352 524 1270 1780 1890 2650 93 3 4 8 0.50 12.6 0.56 14.1 1.39 35.3 1.64 41.7 1.75 44.5 447 665 1508 2068 2244 3077 122 3 2 6 0.54 13.7 0.61 15.5 1.50 38.1 1.78 45.2 1.88 47.8 710 1056 1930 2489 2872 3704 141 3 1 6 0.57 14.5 0.64 16.3 1.57 39.9 1.86 47.2 1.96 49.8 939 1397 2150 2709 3199 4032 161 3 1/0 6 0.61 15.6 0.67 17.1 1.65 41.9 1.94 49.3 2.06 52.3 875 1302 2360 3047 3511 4534 184 3 2/0 6 0.65 16.5 0.72 18.3 1.80 45.7 2.09 53.1 2.19 55.6 1340 1994 2890 3578 4300 5324 212 3 3/0 4 0.70 17.8 0.76 19.3 1.90 48.3 2.19 55.6 2.29 58.2 1798 2675 3360 4048 5000 6023 242 3 4/0 4 0.76 19.2 0.82 20.7 1.99 50.5 2.28 57.9 2.39 60.7 2130 3169 3815 4620 5676 6875 278 3 250 4 0.81 20.6 0.87 22.1 2.15 54.6 2.44 62.0 2.58 65.6 2494 3711 4309 5237 6411 7793 306 3 350 3 0.90 22.9 0.96 24.4 2.31 58.7 2.60 66.1 2.73 69.4 3471 5164 5538 6466 8240 9622 373 3 500 3 1.02 25.9 1.08 27.4 2.60 66.0 2.89 73.4 3.03 76.9 4884 7268 6982 8038 10389 11960 450 3 750 2 1.19 30.2 1.25 31.7 2.98 75.7 3.27 83.1 3.42 86.9 7440 11071 10117.5 11301 15055 16815 545 3 1000 1 1.35 34.3 1.44 36.6 3.42 86.9 3.71 94.3 3.86 98.1 9860 14678 13300 14870 19790 22130 640 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). Ampacity based on CE Code Table D17N and Rule 4-004.
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait