94 Industrial Cables SPEC 8400 Feb, 2025 HVTECK TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored 15 kV CSA HVTECK, 133% Ins. Level, 220 Mils, Single Conductor Product Construction: Conductor: • 2 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • Black semi-conducting thermosetting layer, applied in a triple extrusion process, plus a concentric serving of solid copper wires acting as both a drain wire shield and a grounding (bonding) conductor Ground (Bonding) Conductor: • The conductor is a concentric serving of solid copper wires applied over the thermosetting insulation shield Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NO. OF COND. COND. SIZE (AWG/ kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/AL ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 2 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—133% INS. LEVELS, 220 MILS INS. (5.59 mm)—15 kV 1 2 6 0.76 19.3 0.83 21.1 1.09 27.7 1.34 34.1 1.43 36.4 286 426 1028 1530 198 1 1 4 0.79 20.1 0.86 21.9 1.12 28.4 1.37 34.8 1.46 37.1 391 582 1170 1740 225 1 1/0 4 0.82 20.8 0.88 22.3 1.18 30.0 1.43 36.3 1.53 38.8 464 691 1258 1872 255 1 2/0 4 0.86 21.8 0.92 23.3 1.22 30.9 1.47 37.3 1.56 39.5 551 820 1343 1999 291 1 3/0 3 0.91 23.0 0.97 24.5 1.27 32.2 1.52 38.5 1.61 41.0 694 1033 1525 2270 327 1 4/0 3 0.96 24.4 1.02 25.9 1.32 33.6 1.61 40.9 1.73 44.0 832 1238 1763 2623 373 1 250 2 1.02 25.9 1.08 27.4 1.38 35.1 1.66 42.2 1.76 44.7 989 1472 2010 2991 417 1 350 1 1.11 28.2 1.17 29.7 1.49 37.9 1.78 45.2 1.90 48.3 1366 2032 2444 3636 491 1 500 1/0 1.22 31.0 1.28 32.6 1.58 40.2 1.87 47.6 1.99 50.6 1905 2835 3052 4542 562 1 750 2/0 1.40 35.5 1.46 37.1 1.85 47.1 2.14 54.4 2.26 57.5 2782 4139 4191 6236 642 1 1000 2/0 1.57 39.8 1.63 41.3 2.07 52.6 2.36 60.0 2.50 63.6 3567 5308 5305 7894 740 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait