95 Industrial Cables SPEC 8425 Feb, 2025 HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 15 kV CSA HVTECK, 100% Ins. Level, 175 Mils, Three Conductor Product Construction: Conductor: • 2 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NO. OF COND. COND. SIZE (AWG/kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/1000 FT kg/km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm AL STEEL AL STEEL 2 AWG THRU 1000 kcmil—THREE CONDUCTOR—100% INS. LEVELS, 175 MILS INS. (4.45 mm)—15 kV 3 2 6 0.66 16.8 0.72 18.3 1.83 46.4 2.12 53.7 2.24 56.8 710 1056 2358 3113 3508 4633 141 3 1 6 0.69 17.5 0.76 19.3 1.89 48.0 2.18 55.4 2.27 57.7 955 1421 2620 3376 3899 5023 161 3 1/0 6 0.73 18.5 0.79 20.1 1.97 50.0 2.26 57.4 2.35 59.7 1163 1731 2900 3656 4315 5440 184 3 2/0 6 0.77 19.5 0.828 21.3 2.06 52.3 2.35 59.5 2.49 62.5 1340 1994 3199 4089 4760 6085 212 3 3/0 4 0.82 20.8 0.88 22.4 2.16 54.9 2.44 62.0 2.57 65.3 1812 2697 3840 4840 5720 7200 242 3 4/0 4 0.87 22.0 0.93 23.7 2.27 57.7 2.56 65.1 2.68 68.1 2228 3316 4360 5410 6490 8050 278 3 250 4 0.93 23.5 0.99 25.2 2.38 60.5 2.68 68.1 2.79 70.9 2598 3866 4880 5990 7260 8910 306 3 350 3 1.06 26.9 1.15 29.2 2.73 69.4 3.02 76.7 3.14 79.8 3587 5338 6210 7430 9240 11060 373 3 500 3 1.14 29.0 1.23 31.2 2.97 75.5 3.26 82.8 3.40 86.4 5013 7460 8549 9550 12721 14200 450 3 750 2 1.32 33.6 1.41 35.9 3.35 85.1 3.64 92.5 3.77 95.8 7446 11081 11100 12640 16520 18810 545 3 1000 1 1.47 37.4 1.56 39.6 3.72 94.5 3.97 100.8 4.17 105.9 9376 13953 13890 15580 20670 23180 640 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait