96 Industrial Cables SPEC 8450 Feb, 2025 HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 15 kV CSA HVTECK, 133% Ins. Level, 220 Mils, Three Conductor Product Construction: Conductor: • 2 AWG thru 750 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) • ICEA T-29-520 (210,000 BTU/hr) Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NO. OF COND. COND. SIZE (AWG/ kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/1000 FT kg/km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm AL STEEL AL STEEL 2 AWG THRU 750 kcmil—THREE CONDUCTOR—133% INS. LEVEL, 220 MILS INS. (5.59 mm)—15 kV 3 2 6 0.75 19.1 0.81 20.6 2.02 51.4 2.31 58.8 2.42 61.5 710 1056 2618 3451 3896 5136 141 3 1 6 0.78 19.9 0.84 21.4 2.06 52.2 2.35 59.6 2.46 62.4 875 1302 2702 3533 4021 5258 161 3 1/0 6 0.82 20.8 0.88 22.3 2.17 55.0 2.46 62.4 2.60 66.0 1080 1607 3228 4285 4803 6377 184 3 2/0 6 0.86 21.8 0.92 23.4 2.22 56.3 2.51 63.7 2.64 67.0 1340 1994 3555 4447 5289 6617 212 3 3/0 4 0.91 23.1 0.98 24.9 2.36 59.9 2.65 67.3 2.77 70.4 1717 2554 4140 5230 6160 7782 242 3 4/0 4 0.96 24.4 1.03 26.2 2.47 62.7 2.76 70.1 2.88 73.2 2130 3169 4680 5810 6964 8645 278 3 250 4 1.02 25.8 1.08 27.3 2.58 65.5 2.87 72.9 3.01 76.5 2494 3711 4960 6008 7380 8940 306 3 350 3 1.11 28.1 1.25 31.6 2.75 69.9 3.04 77.3 3.17 80.6 3471 5164 6296 7393 9369 11000 373 3 500 3 1.22 31.0 1.28 32.6 3.05 77.6 3.34 84.9 3.50 88.8 4884 7268 8213 9424 12221 14023 450 3 750 2 1.39 35.4 1.45 36.9 3.48 88.4 3.77 95.7 3.94 100.1 7296 10857 10763 11974 16015 17817 545 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).
Powered by Prysmian North America
Industrial Cable
| Title Name |
Pages |
Delete |
Url |
| Empty |
Ai generated response may be inaccurate.
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success.
Downloading PDF
Generating your PDF, please wait...
This process might take longer please wait