99 Industrial Cables HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 28 kV (133% Ins. Level) / 35 kV (100% Ins. Level) 345 Mils, CSA HVTECK, Three Conductor SPEC 8525 Feb, 2025 Product Construction: Conductor: • 1/0 AWG thru 350 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • This consists of a semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK √√® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black or as requested Options: • 105˚C TRXLPE Insulation • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 MV68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing NO. OF COND. COND. SIZE (AWG/kcmil) GROUND WIRE SIZE (AWG) NOMINAL DIAMETER (OVER) COPPER WEIGHT NET WEIGHT W/ARMOR OUTDOOR AMPACITY** (40˚C AMBIENT) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE LBS/ 1000 FT kg/ km LBS/1000 FT kg/km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm AL STEEL AL STEEL 1/0 AWG THRU 350 kcmil—THREE CONDUCTOR— 28 kV (133% INS. LEVEL) / 35 kV (100% INS. LEVEL), 345 MILS INS. (8.76 mm) 3 1/0 6 1.08 27.5 1.17 29.7 2.76 70.2 3.05 77.5 3.18 80.8 1200 1786 4360 5620 6490 8370 187 3 2/0 6 1.12 28.5 1.21 30.8 2.92 74.2 3.21 81.6 3.36 85.4 1466 2182 4950 6280 7370 9350 215 3 3/0 4 1.16 29.7 1.22 32.0 2.96 76.7 3.25 84.1 3.42 87.9 1717 2750 5047 6243 8160 10210 245 3 4/0 4 1.22 31.0 1.31 33.3 3.14 79.6 3.43 87.2 3.58 90.9 2130 3369 6090 7510 9060 11180 281 3 250 4 1.27 32.3 1.37 34.8 3.26 82.9 3.55 90.2 3.70 94.0 2494 3921 6660 8140 9910 12120 310 3 350 3 1.42 36.1 1.51 38.4 3.56 90.5 3.85 97.8 4.00 101.6 3471 5389 7960 9540 11840 14190 377 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004).