SPEC 8225 September, 2016 TECK90 TRXLPE/PVC/AIA/PVC, Power, Unshielded, Armored 5 kV, CSA TECK90, Single Conductor Compliances: Industry Compliances: • CSA Standard C22.2 No. 131 and No. 174 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE), Type RW90 Ground (Bonding) Conductor: • The conductor is a concentric serving of solid bare copper wires applied over the insulation Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® AG14 flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) • For wiring in all hazardous locations when used with certified HL cable glands Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Meets cold bend and impact tests at -40˚C CATALOG NUMBER 17496.100600* 17496.100400* 17496.100300* 17496.100200* 17496.100100* 17496.105100* 17496.105200* 17496.105300* 17496.105400* 17496.106000* 17496.106200* 17496.106500* 17496.107000* COND. NO. OF (AWG/ kcmil) 6 4 3 2 1 COND. SIZE GROUND WIRE SIZE (AWG) 1/0 2/0 3/0 4/0 250 350 8 6 6 6 4 4 4 3 3 2 1 INSULATION NOMINAL DIAMETER (OVER) ARMOR Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing COPPER WEIGHT CABLE INCHES mm INCHES mm INCHES mm 0.39 10.0 0.76 19.3 0.85 21.6 0.43 10.5 0.84 21.4 0.93 23.7 0.46 11.7 0.86 21.9 0.95 24.2 0.49 12.5 0.89 22.6 0.98 24.9 0.52 13.3 0.93 23.6 1.02 25.9 0.56 14.2 0.96 24.4 1.06 26.9 0.60 15.2 1.03 26.2 1.13 28.7 0.64 16.3 1.08 27.5 1.18 30.0 0.70 17.8 1.16 29.5 1.26 32.0 1000 FT 143 223 229 301 405 474 561 708 847 LBS/ kg/ km 213 332 341 448 603 705 835 1000 FT 370 490 540 590 720 800 900 LBS/ kg/ km 6 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—UNSHIELDED—90 MILS INS. (2.29 mm)—5 kV 1 1 1 1 1 1 1 1 1 1 1 1 1 550 730 800 890 500 1/0 750 2/0 0.75 19.1 1.24 31.5 1.34 34.1 1012 0.85 21.5 1.34 34.0 1.44 36.6 1388 0.97 24.6 1.49 37.9 1.59 40.4 1548 1.15 29.2 1.68 42.7 1.78 45.2 2243 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. **Ampacity is based on CE Code Part 1, Table 1 (single conductor in free air) and Rule 4-004. 1054 1261 1506 2066 2304 3338 1130 1330 1530 1960 2570 3900 1060 1190 1350 1680 1970 2280 2910 3830 5800 NET WEIGHT W/AL ARMOR AMPACITY** (30˚C AMBIENT) 105 140 165 190 220 260 300 350 405 455 570 700 885 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait