SPEC 8325 September, 2016 HVTECK TRXLPE/Tape Shield/PVC/AIA/PVC, Power, Shielded, Armored 5 kV, CSA HVTECK, 100% Ins. Level, 90 Mils, Three Conductor Compliances: Industry Compliances: • CSA Standard C68.10 Product Construction: Conductor: • 6 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • A semi-conducting thermosetting layer, applied in a triple extrusion process, plus a helically applied gapped copper tape • Color-coded: black, red or blue colored tape placed longitudinally under the copper tape shield Ground (Bonding) Conductor: • The conductor consists of one uninsulated stranded bare copper conductor Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black CATALOG NUMBER COND. NO. OF (AWG/ kcmil) 17496.740600* 3 6 17496.740400* 3 4 17496.740200* 3 2 17496.740100* 3 1 COND. SIZE GROUND WIRE SIZE Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), orange Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C NOMINAL DIAMETER (OVER) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE (AWG) INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km COPPER WEIGHT NET WEIGHT W/ARMOR LBS/1000 FT kg/km AL STEEL AL STEEL Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) • ICEA T-29-520 (210,000 BTU/hr) Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing AMPACITY** (40˚C AMBIENT) 6 AWG THRU 1000 kcmil—THREE CONDUCTOR—SHIELDED, 100% INS. LEVEL, 90 MILS INS. (2.29 mm)—5 kV 8 0.39 10.0 0.47 11.9 1.17 29.7 1.45 36.9 1.54 39.2 349 519 1120 1590 1670 2360 8 0.43 10.5 0.51 13.0 1.26 32.0 1.54 39.1 1.63 41.4 503 749 1350 1850 1670 2760 122 6 0.49 12.5 0.57 14.5 1.39 35.3 1.67 42.4 1.77 45.0 771 1147 1740 2290 2590 3410 141 6 0.52 13.3 0.60 15.3 1.45 36.9 1.73 43.9 1.83 46.5 939 1397 1960 2540 2920 3780 161 93 17496.745100* 3 1/0 6 0.56 14.2 0.63 16.0 1.53 38.9 1.81 46.0 1.91 48.5 1148 1708 2290 3010 3410 4490 184 17496.745200* 3 2/0 6 0.60 15.2 0.67 17.0 1.62 41.2 1.91 48.5 2.01 51.1 1414 2104 2620 3380 3900 5030 212 17496.745300* 3 3/0 4 0.64 16.3 0.71 18.1 1.78 45.2 2.07 52.6 2.17 55.1 1798 2668 3210 4040 4780 6020 242 17496.745400* 3 4/0 4 0.70 17.8 0.76 19.3 1.90 48.3 2.19 55.6 2.29 58.2 2212 3292 3720 4600 5530 6840 278 17496.746000* 3 250 4 0.75 19.1 0.82 20.8 2.01 51.1 2.30 58.4 2.43 61.8 2583 3844 4300 5240 6400 7800 306 17496.746200* 3 350 3 0.85 21.5 0.96 24.4 2.32 58.9 2.61 66.3 2.74 69.6 3569 5311 5480 6520 8160 9700 373 17496.746500* 3 500 3 0.97 24.6 1.04 26.4 2.48 63.0 2.77 70.4 2.90 73.7 4998 7438 7130 8280 10610 12320 450 17496.747000* 3 750 2 1.15 29.2 1.24 31.5 2.98 75.7 3.27 83.1 3.42 86.9 7440 11072 10330 11700 15370 17410 545 17496.747500* 3 1000 1 1.30 33.0 1.39 35.3 3.31 84.1 3.60 91.5 3.75 95.3 9860 14674 13080 14600 19460 21730 640 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). Ampacity based on CE Code Table D17N and Rule 4-004. OUTDOOR Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait