SPEC 8375 September, 2016 HVTECK TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored 15 kV, CSA HVTECK, 100% Ins. Level, 175 Mils, Single Conductor Compliances: Industry Compliances: • CSA Standard C68.10 Product Construction: Conductor: • 2 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • Black semi-conducting thermosetting layer, applied in a triple extrusion process, plus a concentric serving of solid copper wires acting as both a drain wire shield and a grounding (bonding) conductor Ground (Bonding) Conductor: • The conductor is a concentric serving of solid copper wires applied over the thermosetting insulation shield Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black CATALOG NUMBER COND. 17496.810200* 1 17496.810100* 1 NO. OF (AWG/ kcmil) COND. SIZE GROUND WIRE SIZE (AWG) Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C NOMINAL DIAMETER (OVER) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km 1000 FT LBS/ kg/ km 17496.815100* 1 1/0 17496.815200* 1 2/0 17496.815300* 1 3/0 17496.815400* 1 4/0 17496.816000* 1 250 17496.816200* 1 350 6 0.66 16.7 0.73 18.6 0.99 25.3 1.24 31.5 1.33 33.8 259 385 950 1420 4 0.69 17.5 0.76 19.3 1.03 26.1 1.28 32.5 1.37 34.8 391 582 1080 1600 4 0.73 18.5 0.80 20.3 1.06 27.0 1.31 33.3 1.40 35.6 460 685 1170 1750 4 0.77 19.5 0.84 21.3 1.10 27.9 1.35 34.3 1.44 36.6 545 811 1290 1920 3 0.82 20.8 0.88 22.4 1.15 29.2 1.40 35.6 1.49 37.9 688 1024 1470 2190 3 0.87 22.0 0.94 23.9 1.21 30.6 1.46 37.1 1.55 39.4 824 1226 1640 2450 2 0.93 23.5 0.99 25.2 1.28 32.5 1.53 38.9 1.63 41.4 944 1405 1900 2830 1 1.07 27.2 1.15 29.2 1.43 36.3 1.71 43.5 1.81 46.0 1352 2012 2370 3530 COPPER WEIGHT NET WEIGHT W/AL ARMOR 2 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—100% INS. LEVELS, 175 MILS INS. (4.45 mm)—15 kV 2 1 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) • ICEA T-29-520 (210,000 BTU/hr) Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing AMPACITY** (40˚C AMBIENT) 17496.816500* 1 500 1/0 1.14 29.0 1.23 31.2 1.54 39.1 1.83 46.5 1.93 49.1 1887 2808 3080 4590 17496.817000* 1 750 2/0 1.32 33.6 1.41 35.9 1.78 45.2 2.07 52.6 2.17 55.2 2754 4099 4240 6320 17496.817500* 1 1000 2/0 1.48 37.6 1.57 39.9 1.93 49.0 2.22 56.4 2.32 59.0 3532 5256 5280 7860 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). 198 225 255 291 327 373 417 491 562 642 740 OUTDOOR Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait