SPEC 8400 September, 2016 HVTECK TRXLPE/Wire Shield/PVC/AIA/PVC, Power, Shielded, Armored 15 kV, CSA HVTECK, 133% Ins. Level, 220 Mils, Single Conductor Product Construction: Conductor: • 2 AWG thru 1000 kcmil bare copper compact Class B strand Strand Shield: • A thermoset semi-conducting strand shield is extruded over the conductor Insulation: • Tree-Retardant Cross-linked Polyethylene (TRXLPE) Insulation Shield: • Black semi-conducting thermosetting layer, applied in a triple extrusion process, plus a concentric serving of solid copper wires acting as both a drain wire shield and a grounding (bonding) conductor Ground (Bonding) Conductor: • The conductor is a concentric serving of solid copper wires applied over the thermosetting insulation shield Inner Jacket: • Lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black Armor: • Aluminum Interlocked Armor (AIA) Overall Jacket: • Lead-free, ACID-FLAME-CHECK ✓✓® flame- retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), red Options: • Galvanized Steel Interlocked Armor (GSIA) CATALOG NUMBER COND. 17496.216500* 1 17496.820100* 1 NO. OF (AWG/ kcmil) COND. SIZE GROUND WIRE SIZE (AWG) Applications: • For wiring in all hazardous locations when used with certified HL cable glands • For exposed and concealed wiring in dry, damp or wet locations • For use in ventilated, non-ventilated and ladder- type cable trays in dry, damp or wet locations • For direct earth burial (with protection as required by inspection authority) Features: • Rated at 90˚C wet or dry • Excellent crush, oil and chemical resistance • Provides long service life • Cost-effective alternative to installations in conduit • Meets cold bend and impact tests at -40˚C Compliances: Industry Compliances: • CSA Standard C68.10 Flame Test Compliances: • CSA FT1 and FT4 • IEEE 383 (70,000 BTU/hr) • UL 1581 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 • ICEA T-30-520 (70,000 BTU/hr) • ICEA T-29-520 (210,000 BTU/hr) NOMINAL DIAMETER (OVER) INSULATION INSULATION SHIELD INNER JACKET ARMOR CABLE INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1000 FT LBS/ kg/ km 1000 FT LBS/ kg/ km 17496.825100* 1 1/0 17496.825200* 1 2/0 17496.825300* 1 3/0 17496.825400* 1 4/0 17496.826000* 1 250 17496.826200* 1 350 6 0.76 19.3 0.83 21.1 1.09 27.7 1.34 34.1 1.43 36.4 286 426 1028 1530 4 0.79 20.1 0.86 21.9 1.12 28.4 1.37 34.8 1.46 37.1 391 582 1170 1740 4 0.83 21.1 0.89 22.6 1.16 29.4 1.41 35.8 1.50 38.1 459 683 1270 1890 4 0.86 21.8 0.93 23.6 1.20 30.4 1.45 36.9 1.54 39.2 546 813 1390 2060 3 0.91 23.0 0.98 24.9 1.25 31.7 1.50 38.1 1.59 40.4 693 1031 1570 2340 3 0.96 24.3 1.03 26.2 1.30 33.0 1.58 40.2 1.68 42.7 830 1235 1780 2650 2 1.02 25.8 1.08 27.5 1.38 35.0 1.66 42.2 1.76 44.7 989 1472 2010 2990 1 1.12 28.3 1.20 30.5 1.50 38.0 1.78 45.2 1.88 47.8 1228 1827 2490 3700 COPPER WEIGHT NET WEIGHT W/AL ARMOR Compliances (cont'd.): Other Compliances: • Hazardous Location Rating: HL • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • For Canadian customers, lengths are provided on returnable wood or steel reels that require a deposit. Extra charges apply for lagging, pulling eyes, paralleling and plexing • For U.S. customers, material cut to length and shipped on non-returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing OUTDOOR AMPACITY** (40˚C AMBIENT) 2 AWG THRU 1000 kcmil—SINGLE CONDUCTOR—133% INS. LEVELS, 220 MILS INS. (5.59 mm)—15 kV 2 1 17496.826500* 1 500 1/0 1.24 31.5 1.32 33.6 1.65 41.8 1.94 49.3 2.04 51.9 1896 2821 3220 4790 17496.827000* 1 750 2/0 1.42 36.0 1.51 38.3 1.89 48.0 2.18 55.4 2.28 57.9 2766 4116 4390 6530 17496.827500* 1 1000 2/0 1.57 39.9 1.68 42.6 2.05 52.1 2.34 59.5 2.48 63.0 3552 5286 5550 8260 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. ** Open circuit (shield/armor) is assumed. Ampacities at other voltage levels do not vary significantly. Special approval by local electrical inspection authorities may be required (Ref. CE Code Part 1, Appendix B, Rule 4-004). 198 225 255 291 327 373 417 491 562 642 740 Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait