SPEC 9700 July, 2014 CCW Armored Power, 2.4 kV, Nonshielded, 3/C VFD UL Type MC-HL or MV-90, EPR, 105°C, Cable Tray Use, Sunlight-Resistant Direct Burial, ABS CWCMC ® COND. SIZE CATALOG NUMBER 9700.00803312 9700.00603310 9700.00403310 9700.00203310 AWG (kcmil) (8.36 mm²) 3 90 2.3 0.36 9.1 3 x #12 0.77 19.6 0.97 24.6 50 1.27 1.08 27.4 570 848 59 85 6 (7/W) 8 (7/W) (21.2 mm²) 3 90 2.3 0.43 10.8 3 x #10 0.97 24.6 1.19 30.2 50 1.27 1.30 33.0 965 1,436 105 135 2 (7/W) (13.3 mm²) 3 90 2.3 0.38 9.6 3 x #10 0.85 21.6 1.06 26.9 50 1.27 1.17 29.7 745 1,109 79 105 4 (7/W) (33.6 mm²) 3 90 2.3 0.48 12.1 3 x #10 1.10 27.9 1.34 34.0 50 1.27 1.45 36.8 1,275 1,897 140 180 9700.00103308 1 (19/W) (42.4 mm²) 3 90 2.3 0.52 13.1 3 x #8 1.16 29.5 1.42 36.1 50 1.27 1.53 38.9 1,525 2,269 160 200 9700.11003308 1/0 (19/W) (53.5 mm²) 3 90 2.3 0.55 13.9 3 x #8 1.23 31.2 1.51 38.4 60 1.52 1.65 41.9 1,840 2,738 185 230 9700.21003308 2/0 (19/W) (67.4 mm²) 3 90 2.3 0.59 14.9 3 x #8 1.33 33.8 1.60 40.6 60 1.52 1.73 43.9 2,165 3,222 215 260 9700.41003307 4/0 (19/W) (107 mm²) 3 90 2.3 0.69 17.4 3 x #7 1.53 38.9 1.83 46.5 60 1.52 1.96 49.8 3,080 4,584 285 335 9700.25003307 250 (37/W) (127 mm²) 3 90 2.3 0.74 18.7 3 x #7 1.64 41.7 1.96 49.8 60 1.52 2.09 53.1 3,475 5,171 320 365 9700.35003306 350 (37/W) (177 mm²) 3 90 2.3 0.83 21.0 3 x #6 1.86 47.2 2.19 55.6 60 1.52 2.32 58.9 4,710 7,009 395 440 9700.50003305 500 (37/W) (253 mm²) 3 90 2.3 0.95 24.0 3 x #5 2.10 53.3 2.45 62.2 75 1.91 2.61 66.3 6,410 9,539 485 530 9700.75003304 750 (61/W) (380 mm²) 3 90 2.3 1.12 28.3 3 x #4 2.51 63.8 2.93 74.4 75 1.91 3.10 78.7 9,225 13,728 615 650 9700.10003304 1000 (61/W) (507 mm²) 3 90 2.3 1.27 32.2 3 x #4 2.90 73.7 3.41 86.6 80 2.03 3.59 91.2 12,080 17,977 705 730 Dimensions and weights are nominal, subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 90°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 90°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. COND. mils mm INCHES mm AWG INCHES mm INCHES mm mils mm INCHES mm 3/C WITH GROUND MC-HL OR MV-90, 90 MILS EPR, 2.4 kV, YELLOW JACKET NO. OF INSULATION THICKNESS NOMINAL O.D. OVER INSULATION GROUND BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT kg/1000 m AMPACITY IN AIR¹ DIRECT BURIAL² Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait