SPEC 9815 October, 2014 CCW Armored Power, 8 kV 133%, Shielded, 3/C VFD ® UL Type MC-HL or MV-105, CSA Type HL, EPR, 105°C, Cable Tray Use, Sunlight-Resistant Direct Burial, ABS CWCMC COND. SIZE CATALOG NUMBER AWG (kcmil) NO. OF COND. INSULATION THICKNESS NOMINAL O.D. OVER INSULATION GROUND BARE NOMINAL CORE O.D. ARMOR O.D. NOMINAL THICKNESS JACKET OVERALL O.D. mils mm INCHES mm AWG INCHES mm INCHES mm mils mm INCHES mm NOMINAL APPROXIMATE NET WEIGHT LBS/1000 FT 3/C WITH GROUND MC-HL OR MV-105, 140 MILS EPR, 8 kV 133% INSULATION LEVEL 9815.00603310 6 (7/W) (13.3 mm²) 3 140 3.6 0.48 12.2 3 x #10 1.20 30.5 1.60 40.6 60 1.52 1.73 43.9 1,350 2,009 105 120 9815.00403310 4 (7/W) (21.2 mm²) 3 140 3.6 0.53 13.5 3 x #10 1.29 32.8 1.70 43.2 60 1.52 1.83 46.5 1,600 2,381 135 155 9815.00203310 2 (7/W) (33.6 mm²) 3 140 3.6 0.58 14.7 3 x #10 1.42 36.1 1.85 47.0 60 1.52 1.98 50.3 2,000 2,976 185 200 9815.00103308 1 (19/W) (42.4 mm²) 3 140 3.6 0.62 15.7 3 x #8 1.52 38.6 1.93 49.0 60 1.52 2.06 52.3 2,275 3,386 210 225 9815.11003308 1/0 (19/W) (53.5 mm²) 3 140 3.6 0.65 16.5 3 x #8 1.61 40.9 2.03 51.6 60 1.52 2.16 54.9 2,600 3,869 240 255 9815.21003308 2/0 (19/W) (67.4 mm²) 3 140 3.6 0.69 17.5 3 x #8 1.66 42.2 2.14 54.4 60 1.52 2.27 57.7 2,950 4,390 275 290 9815.41003307 4/0 (19/W) (107 mm²) 9815.25003306 250 (37/W) (127 mm²) 9815.35003306 350 (37/W) (177 mm²) 9815.50003305 500 (37/W) (253 mm²) 9815.75003304 750 (61/W) (380 mm²) 9815.10003304 1000 (61/W) (507 mm²) 3 140 3.6 0.79 20.1 3 x #7 1.87 47.5 2.40 61.0 75 1.91 2.56 65.0 4,025 5,990 360 375 3 140 3.6 0.85 21.6 3 x #6 2.06 52.3 2.59 65.8 75 1.91 2.75 69.9 4,600 6,846 400 410 3 140 3.6 0.94 23.9 3 x #6 2.15 54.6 2.85 72.4 75 1.91 3.01 76.5 5,800 8,631 490 495 3 140 3.6 1.06 26.9 3 x #5 2.44 62.0 3.19 81.0 85 2.16 3.37 85.6 7,800 11,608 600 590 3 140 3.6 1.26 32.0 3 x #4 3.19 81.0 3.68 93.5 85 2.16 3.86 98.0 10,750 15,998 745 720 3 140 3.6 1.42 36.1 3 x #4 3.48 88.4 3.98 101.1 85 2.16 4.16 105.7 13,550 20,165 860 810 Dimensions and weights are nominal; subject to industry tolerances. ¹ In-air ampacities are per NEC Table 310.60(C)(71) for three insulated copper conductors rated 105°C, cabled with an overall covering and isolated in air at 40°C ambient temperature. ² Direct burial ampacities are per NEC Table 310.60(C)(83) for three insulated copper conductors rated 105°C, cabled within an overall covering and directly buried in earth at 20°C ambient earth temperature. kg/1000 m AMPACITY IN AIR¹ DIRECT BURIAL² Phone: 888-593-3355 www.generalcable.com
Powered by Prysmian North America
Industrial Cable
Title Name |
Pages |
Delete |
Url |
Empty |
Search Text Block
Page #page_num
#doc_title
Hi $receivername|$receiveremail,
$sendername|$senderemail wrote these comments for you:
$message
$sendername|$senderemail would like for you to view the following digital edition.
Please click on the page below to be directed to the digital edition:
$thumbnail$pagenum
$link$pagenum
Your form submission was a success. You will be contacted by Washington Gas with follow-up information regarding your request.
This process might take longer please wait