42 Industrial Cables Product Construction: Conductor: • 6 AWG thru 1000 kcmil annealed bare copper compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • Annealed copper tape with an overlap of 25% Jacket: • Flame-retardant, moisture- and sunlight- resistant Chlorinated Polyethylene (CPE) Options: • STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications Applications (cont'd): • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • Easy Glider® low friction technology for easy cable pulling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8-13 (AEIC CS8-20, Optional) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing SPEC 6175 Feb, 2025 Uniblend® CPE EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded 5 kV and 8 kV UL Type MV-105, 133%/100% Ins. Levels, 115 Mils CATALOG NUMBER COND. SIZE (AWG/ kcmil) NOMINAL CONDUCTOR DIAMETER INSULATION DIAMETER INCHES NOMINAL JACKET THICKNESS NOMINAL CABLE COPPER WEIGHT AMPACITY CONDUIT SIZING (4) (INCHES) DIAMETER WEIGHT CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3) INCHES MIN. MAX. IN mm IN mm LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km 90˚C 105˚C 90˚C 105˚C 90˚C 105˚C 5 kV AND 8 kV, UL TYPE MV-105, 133%/100% INS. LEVELS, 115 MILS 17101.120605 6 0.17 0.415 0.490 0.060 1.52 0.66 16.76 297 442 124 185 83 93 90 97 - - 2 17101.120405 4 0.21 0.455 0.535 0.060 1.52 0.71 18.03 368 547 176 262 110 120 115 125 - - 2 17101.120205 2 0.27 0.510 0.590 0.060 1.52 0.76 19.30 471 700 257 382 150 165 155 165 - - 2.5 17101.120105 1 0.30 0.545 0.620 0.060 1.52 0.79 20.07 539 802 313 465 170 190 175 185 - - 2.5 17101.125105 1/0 0.34 0.580 0.655 0.060 1.52 0.83 21.08 622 925 383 570 195 215 200 215 195 220 2.5 17101.125205 2/0 0.38 0.620 0.695 0.060 1.52 0.87 22.10 722 1074 472 702 225 255 230 245 225 250 2.5 17101.125305 3/0 0.42 0.665 0.745 0.080 2.03 0.95 24.13 877 1306 583 868 260 290 260 275 260 290 3 17101.135405 4/0 0.48 0.720 0.795 0.080 2.03 1.00 25.40 1044 1554 723 1075 295 330 295 315 300 335 3 17101.136005 250 0.52 0.770 0.850 0.080 2.03 1.06 26.92 1182 1759 846 1259 330 365 325 345 335 370 3 17101.136205 350 0.62 0.870 0.945 0.080 2.03 1.15 29.21 1513 2251 1163 1731 395 440 390 415 415 460 3.5 17101.136505 500 0.74 0.990 1.065 0.080 2.03 1.26 32.00 2026 3016 1635 2433 480 535 465 500 515 575 3.5 17101.137005 750 0.91 1.170 1.250 0.080 2.03 1.43 36.32 2851 4243 2424 3607 585 655 565 610 665 745 4 17101.137505 1000 1.06 1.320 1.400 0.080 2.03 1.61 40.89 3764 5601 3209 4776 675 755 640 690 795 890 5 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(73) of the NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(77) of the NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194 ˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(69), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(69). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions. EASY GLIDER ®