48 Industrial Cables Product Construction: Conductor: • 2 AWG thru 1000 kcmil 1350 aluminum compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • Annealed copper tape with an overlap of 25% Jacket: • Low-friction, lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) Options: • STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications • For use in wet or dry locations when installed in accordance with NEC Applications (cont'd): • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • Easy Glider® low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 -13 (AEIC CS8-20, Optional) • CSA C68.10 • CSA C22.2 No. 230 Type TC-ER (Sizes 1/0 AWG and larger) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing Aluminum Uniblend® PVC EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 15 kV UL Type MV-105, 133% Ins. Level, 220 Mils SPEC 6360 Feb, 2025 EASY GLIDER ® CATALOG NUMBER COND. SIZE (AWG/ kcmil) NOMINAL CONDUCTOR DIAMETER INSULATION DIAMETER INCHES NOMINAL JACKET THICKNESS NOMINAL CABLE ALUMINUM WEIGHT COPPER WEIGHT AMPACITY CONDUIT SIZING (4) (INCHES) DIAMETER WEIGHT CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3) INCHES MIN. MAX. IN mm IN mm LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km 90˚C 105˚C 90˚C 105˚C 90˚C 105˚C 15 kV¥, UL TYPE MV-105, 133% INS. LEVEL, 220 MILS 17031.130208 2 0.27 0.710 0.800 0.080 2.03 1.00 25.40 518 771 62 92 71 106 115 130 120 130 - - 3 17031.130108 1 0.30 0.745 0.830 0.080 2.03 1.01 25.65 488 725 78 116 74 110 130 150 135 145 - - 3 17031.135108 1/0 0.34 0.780 0.865 0.080 2.03 1.07 27.18 600 893 99 147 77 115 150 170 155 165 150 170 3 17031.135208 2/0 0.38 0.820 0.905 0.080 2.03 1.10 27.94 649 966 125 186 81 121 175 200 175 190 175 195 3.5 17031.135308 3/0 0.42 0.865 0.955 0.080 2.03 1.13 28.70 600 892 158 235 85 126 200 225 200 215 205 225 3.5 17031.135408 4/0 0.48 0.920 1.005 0.080 2.03 1.20 30.48 797 1187 199 296 90 134 230 260 230 245 235 265 3.5 17031.136008 250 0.52 0.970 1.060 0.080 2.03 1.26 32.00 1181 1758 234 348 94 140 255 290 250 270 260 290 3.5 17031.136208 350 0.62 1.070 1.155 0.080 2.03 1.36 34.54 1032 1536 329 490 103 153 310 350 305 330 325 360 4 17031.136508 500 0.74 1.190 1.275 0.080 2.03 1.47 37.34 1355 2016 468 696 113 168 385 430 370 400 400 450 5 17031.137008 750 0.91 1.370 1.460 0.080 2.03 1.66 42.16 1620 2410 703 1046 129 192 485 540 455 490 515 585 5 17031.137508 1000 1.06 1.520 1.610 0.110 2.79 1.90 48.26 2121 3157 937 1394 140 208 565 640 525 565 620 705 6 Dimensions and weights are nominal; subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 315.60(C)(8) of the 2023 NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 315.60(C)(12) of the 2023 NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 315.60(D)(3) Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger installed with no spacing between cables in an uncovered tray in accordance with Section 392.80(B)(2) of the 2023 NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 315.60(C)(4), operating temperature denoted in column header. (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has not been considered but should be checked for individual installations. ¥ 100% insulation level is available upon request. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions.