50 Industrial Cables SPEC 6375 Feb, 2025 Uniblend® CPE EPR/Copper Tape Shield/CPE, Medium-Voltage Power, Shielded 15 kV UL Type MV-105, 133% Ins. Level, 220 Mils Product Construction: Conductor: • 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • Annealed copper tape with an overlap of 25% Jacket: • Flame-retardant, moisture- and sunlight- resistant Chlorinated Polyethylene (CPE) Options: • STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications • For use in wet or dry locations when installed in accordance with NEC Applications (cont’d): • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • Easy Glider® low friction technology for easy cable pulling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Meets cold bend test at -35˚C • Chemical-resistant • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 -13 (AEIC CS8-20, Optional) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 (Sizes 1/0 AWG and larger) UL Flame Exposure Test • Sizes 1/0 AWG and larger are listed and marked “Sunlight-Resistant FOR CT USE” in accordance with NEC • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing EASY GLIDER ® CATALOG NUMBER COND. SIZE (AWG/ kcmil) NOMINAL CONDUCTOR DIAMETER INSULATION DIAMETER INCHES NOMINAL JACKET THICKNESS NOMINAL CABLE COPPER WEIGHT AMPACITY CONDUIT SIZING (4) (INCHES) DIAMETER WEIGHT CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3) INCHES MIN. MAX. IN mm IN mm LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km 90˚C 105˚C 90˚C 105˚C 90˚C 105˚C 15 kV¥, UL TYPE MV-105, 133% INS. LEVEL, 220 MILS 17131.130205 2 0.27 0.710 0.800 0.080 2.03 1.00 25.40 656 977 275 409 150 165 155 165 - - 3 17131.130105 1 0.30 0.745 0.830 0.080 2.03 1.03 26.16 730 1086 331 492 170 190 175 185 - - 3 17131.135105 1/0 0.34 0.780 0.865 0.080 2.03 1.06 26.92 819 1219 401 597 195 215 200 215 195 220 3 17131.135205 2/0 0.38 0.820 0.905 0.080 2.03 1.10 27.94 927 1379 490 729 225 255 230 245 225 250 3.5 17131.135305 3/0 0.42 0.865 0.955 0.080 2.03 1.15 29.21 1064 1584 601 895 260 290 260 275 260 290 3.5 17131.135405 4/0 0.48 0.920 1.005 0.080 2.03 1.20 30.48 1239 1844 741 1102 295 330 295 315 300 335 3.5 17131.136005 250 0.52 0.970 1.060 0.080 2.03 1.26 32.00 1386 2062 864 1286 330 365 325 345 335 370 3.5 17131.136205 350 0.62 1.070 1.155 0.080 2.03 1.35 34.29 1731 2576 1181 1758 395 440 390 415 415 460 4 17131.136505 500 0.74 1.190 1.275 0.080 2.03 1.47 37.34 2263 3368 1653 2459 480 535 465 500 515 575 5 17131.137005 750 0.91 1.370 1.460 0.080 2.03 1.64 41.66 3114 4634 2442 3634 585 655 565 610 665 745 5 17131.637505 1000 1.06 1.520 1.610 0.110 2.79 1.90 48.26 4208 6263 3227 4803 675 755 640 690 795 890 6 Dimensions and weights are nominal; subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 315.60(C)(7) of the 2023 NEC for triplexed or three single conductor copper cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 315.60(C)(11) of the 2023 NEC for triplexed or three single conductor copper cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 315.60(D)(3) Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger installed with no spacing between cables in an uncovered tray in accordance with Section 392.80(B)(2) of the 2023 NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are based on 75% of the values per Table 315.60(C)(3), operating temperature denoted in column header. (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has not been considered but should be checked for individual installations. ¥ 100% insulation level is available upon request. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions.