53 Industrial Cables Product Construction: Conductor: • 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • Annealed copper tape with an overlap of 25% Grounding Conductor: • 1 bare grounding conductor may be in contact with metallic shielding tape Overall Jacket: • Flame-retardant, moisture- and sunlight- resistant Chlorinated Polyethylene (CPE) Options: • STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical • In wet or dry locations when installed in accordance with NEC • In aerial, direct burial, conduit, open tray and underground duct installations Features: • Rated at 105˚C • Excellent heat, moisture and sunlight resistance • Outstanding corona resistance • Flexibility for easy handling • Easy Glider® low friction technology for easy cable pulling Features (cont'd): • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 -13 (AEIC CS8-20, Optional) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 (70,000 BTU/hr) • OSHA Acceptable • RoHS Compliant Optional Flame Tests: • IEEE 1202 (70,000 BTU/hr)/CSA FT4 Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing SPEC 6475 Feb, 2025 Uniblend® CPE EPR/Copper Tape Shield with Overall CPE Jacket, Medium-Voltage Power, Shielded 15 kV UL Type MV-105, 133% Ins. Level, 220 Mils, Three Conductor EASY GLIDER ® CATALOG NUMBER COND. SIZE (AWG/ kcmil) NOMINAL CONDUCTOR DIAMETER INSULATION DIAMETER INCHES GROUND WIRE (AWG) NOMINAL JACKET THICKNESS NOMINAL CABLE COPPER WEIGHT AMPACITY DIAMETER WEIGHT CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3) INCHES MIN. MAX. IN mm IN mm LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km 90˚C 105˚C 90˚C 105˚C 90˚C 105˚C 15 kV¥, UL TYPE MV-105, 133% INS. LEVEL, 220 MILS, THREE CONDUCTOR 15593.440205 2 0.27 0.710 0.800 6 0.110 2.79 2.06 52.32 2249 3347 907 1350 145 165 150 160 165 185 15593.445105 1/0 0.34 0.780 0.865 4 0.110 2.79 2.20 55.88 2811 4183 1337 1990 195 215 195 210 215 240 15593.445205 2/0 0.38 0.820 0.905 4 0.110 2.79 2.29 58.17 3154 4694 1604 2386 220 245 220 235 245 275 15593.445405 4/0 0.48 0.920 1.005 3 0.110 2.79 2.50 63.50 4167 6201 2392 3560 290 320 285 305 325 360 15593.446005 250 0.52 0.970 1.060 2 0.110 2.79 2.62 66.55 4775 7106 2805 4175 315 350 310 335 360 400 15593.446205 350 0.62 1.070 1.155 2 0.110 2.79 2.82 71.63 6182 9200 3760 5596 385 430 375 400 435 490 15593.446505 500 0.74 1.190 1.275 1 0.140 3.56 3.12 79.25 7686 11438 5232 7786 470 525 450 485 535 600 15593.447005 750 0.91 1.370 1.460 1/0 0.140 3.56 3.49 88.65 10978 16337 7675 11422 570 635 545 585 670 745 15593.447505 1000 1.06 1.520 1.610 2/0 0.140 3.56 3.86 98.04 13983 20809 10123 15064 650 725 615 660 770 860 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(75) of the NEC for three conductor copper cable in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(79) of the NEC for three conductor copper cable in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on three conductor Type MV-105 cables in single layer in an uncovered tray with maintained spacing of not less than one cable diameter between cables, in accordance with Section 392.80(B)(1) of the NEC at an ambient air temperature of 40˚C (104˚F); the ampacities are per Table 310.60(C)(71), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 95% of the values in NEC Table 310.60(C)(75). ¥ 100% insulation level is available upon request. Note: a) All sizes are “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions.