56 Industrial Cables SPEC 6560 Feb, 2025 Aluminum Uniblend® PVC EPR/Copper Tape Shield/PVC, Medium-Voltage Power, Shielded 25 kV and 35 kV UL Type MV-105, 133%/100% Ins. Levels, 345 Mils Product Construction: Conductor: • 1/0 AWG thru 1000 kcmil 1350 aluminum compact Class B strand Extruded Strand Shield (ESS): • Extruded thermoset semi-conducting stress- control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Metallic Shield: • Annealed copper tape with an overlap of 25% Jacket: • Low-friction, lead-free, flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC) Options: • STRANDFILL® - blocked conductor. Tested in accordance with ICEA T-31-610 Applications: • Superior performance in petrochemical plants, pulp and paper mills, sewage and water treatment plants, environmental protection systems, railroads, mines, utility power generating stations, steel mills, textile plants and other industrial three-phase applications Applications (cont’d): • For use in wet or dry locations when installed in accordance with NEC • For use in aerial, conduit, open tray and underground duct installations • For use in direct burial if installed in a system with a ground conductor that is in close proximity, and conforms with NEC 250.4(A)(5) Features: • Rated at 105˚C • Easy Glider® low friction technology for easy cable pulling • Excellent heat, moisture and sunlight resistance • Excellent flame resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss • Chemical-resistant • Meets cold bend test at -35˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions Compliances: • National Electrical Code (NEC) • UL 1072 • ICEA S-93-639/NEMA WC74 • ICEA S-97-682 • AEIC CS8 -13 (AEIC CS8-20, Optional) • CSA C68.10 • CSA C22.2 No. 230 Type TC-ER (Sizes 1/0 AWG and larger) • UL listed as Type MV-105 for use in accordance with NEC, UL File # E518856 • UL 1685 UL Flame Exposure Test • IEEE 1202 (70,000 BTU/hr)/CSA FT4 • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and triplexing EASY GLIDER ® CATALOG NUMBER COND. SIZE (AWG/ kcmil) NOMINAL CONDUCTOR DIAMETER INSULATION DIAMETER INCHES NOMINAL JACKET THICKNESS NOMINAL CABLE ALUMINUM WEIGHT COPPER WEIGHT AMPACITY CONDUIT SIZING (4) (INCHES) DIAMETER WEIGHT CONDUIT IN AIR (1) UNDERGROUND DUCT (2) TRAY (3) INCHES MIN. MAX. IN mm IN mm LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km LBS/1 000 FT kg/ km 90˚C 105˚C 90˚C 105˚C 90˚C 105˚C 25 kV¥ & 35 kV¥¥, UL TYPE MV-105, 133%/100% INS. LEVEL, 345 MILS 17061.135108 1/0 0.34 1.020 1.120 0.080 2.03 1.32 33.53 857 1275 99 147 97 144 150 170 155 165 150 170 4 17061.135208 2/0 0.38 1.060 1.160 0.080 2.03 1.36 34.54 919 1367 125 186 101 150 175 200 175 190 175 195 4 17061.135308 3/0 0.42 1.105 1.205 0.080 2.03 1.37 34.80 857 1275 158 235 105 156 200 225 200 215 205 225 4 17061.135408 4/0 0.48 1.160 1.260 0.080 2.03 1.46 37.08 1088 1619 199 296 109 162 230 260 230 245 235 265 4 17061.136008 250 0.52 1.210 1.315 0.080 2.03 1.51 38.35 1170 1742 234 349 114 169 255 290 250 270 260 290 5 17061.136208 350 0.62 1.310 1.410 0.080 2.03 1.61 40.89 1350 2009 329 490 122 181 310 350 305 330 325 360 5 17061.136508 500 0.74 1.430 1.530 0.080 2.03 1.73 43.94 1599 2379 468 697 132 197 385 430 370 400 400 450 5 17061.137008 750 0.91 1.610 1.710 0.110 2.79 2.00 50.80 2168 3226 703 1046 148 220 485 540 455 490 515 585 6 17061.137508 1000 1.06 1.760 1.865 0.110 2.79 2.15 54.61 2550 3795 937 1394 161 239 565 640 525 565 620 705 6 Dimensions and weights are nominal. Subject to industry tolerances. * Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery. (1) Ampacities are in accordance with Table 310.60(C)(74) of the NEC for triplexed or three single conductor aluminum cables in isolated conduit in air based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient air temperature of 40˚C (104˚F). (2) Ampacities are in accordance with Table 310.60(C)(78) of the NEC for triplexed or three single conductor aluminum cables in underground ducts (three conductors per duct), based on a conductor temperature of 90˚C (194˚F) or 105˚C (221˚F), temperature denoted in column header, and an ambient earth temperature of 20˚C (68˚F), electrical duct arrangement per Figure 310.60 Detail 1, 100% load factor, and earth thermal resistance (rho) of 90. (3) Ampacities are based on single conductor Type MV-105 sizes #1/0 AWG and larger in an uncovered tray in accordance with Section 392.80(B)(2) of the NEC at an ambient air temperature of 40˚C (104˚F) the ampacities are based on 75% of the values per Table 310.60(C)(70), operating temperature denoted in column header. For cable trays with unventilated covers for more than 6 feet, the ampacities shall not exceed 70% of the values per Table 310.60(C)(70). (4) Based on nominal cable diameters, three single cables in the duct (PVC Schedule 40) with no ground wire and a maximum of 40% fill. Jam ratio has been considered but should be checked for individual installations. ¥ 100% insulation level is available upon request. ¥¥ 133% insulation level is available upon request. Note: a) Sizes smaller than 1/0 AWG do not include “FOR CT USE”. b) The NESC Lightning bolt symbol is on all Uniblend® constructions.