75 Industrial Cables SPEC 7350 July, 2024 Duralox® Uniblend® EPR/AIA/PVC, Power, Shielded, Armored 25 kV UL Type MV-105 or MC, 100% Ins. Level, 260 Mils, Three Conductor Product Construction: Conductors: • 1/0 AWG thru 1000 kcmil bare, copper compact Class B strand Extruded Strand Shield (ESS): • Thermoset semi-conducting extruded stress control layer over conductor Insulation: • Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers Extruded Insulation Shield (EIS): • Thermoset semi-conducting polymeric layer free stripping from insulation Shield: • Annealed copper tape with an overlap of 25% Ground: • Annealed bare copper Class B stranding per ASTM B8 Armor: • Aluminum Interlocked Armor (AIA) Jacket: • Flame-retardant, moisture- and sunlight- resistant Polyvinyl Chloride (PVC), red Options: • Galvanized Steel Interlocked Armor (GSIA) Applications: • Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is the major concern, where maximum performance is demanded, space is limited, ease of installation is critical and fire resistance is necessary • Installed in wet or dry locations, indoors or outdoors, direct burial and in exposed or concealed work • May be used in cable trays or on approved support in protected areas • Permitted for use per NEC Article 330 - Class I, Division 2 - Class II, Division 2 - Class III, Divisions 1 and 2 Features: • Rated at 105˚C wet or dry • Excellent heat and moisture resistance • Outstanding corona resistance • Flexibility for easy handling • High dielectric strength • Low moisture absorption • Electrical stability under stress • Low dielectric loss Features (cont'd.): • Chemical- and radiation-resistant • Excellent crush resistance • Cost-effective alternative to installations in conduit • Meets cold bend test at -40˚C • 105°C rating for continuous operation • 140°C rating for emergency overload conditions • 250°C rating for short circuit conditions • Sunlight-resistant for CT use Compliances: Industry Compliances: • UL 1072 • ICEA S-93-639/NEMA WC74 • AEIC CS8-13 (AEIC CS8-20, Optional) • UL Type MV-105, UL File # E518856 • UL Type MC, UL File # E90496 Flame Test Compliances: • UL 1685 (70,000 BTU/hr) • IEEE 1202 (70,000 BTU/hr) CSA FT4 Other Compliances: • EPA 40 CFR, Part 261 for leachable lead content per TCLP method • OSHA Acceptable • RoHS Compliant Packaging: • Material cut to length and shipped on non- returnable wood reels, while lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit. Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing CATALOG NUMBER NO. OF COND. COND. SIZE (AWG/) kcmil COND. DIA. INCHES INSULATION DIAMETER GRND. WIRE SIZE (AWG) NOM. DIA. (OVER) ARMOR NOMINAL JACKET THICKNESS NOMINAL CABLE O.D. COPPER WEIGHT NET WEIGHT W/AL ARMOR MIN. MAX. LBS/ 1000 FT kg/ km LBS/ 1000 FT kg/ km INCHES mm INCHES mm INCHES mm INCHES mm INCHES mm 1/0 AWG - 1000 kcmil CONDUCTORS 25 kV, 100% INS. LEVEL, 260 MILS INS. 17477.535100* 3 1/0 0.34 0.85 21.6 0.94 23.9 4 2.39 60.8 0.075 1.91 2.56 64.9 1372 2043 3358 5000 17477.535200* 3 2/0 0.38 0.89 22.6 0.99 25.0 4 2.49 63.1 0.075 1.91 2.65 67.2 1389 2067 3469 5161 17477.535400* 3 4/0 0.48 0.99 25.1 1.08 27.4 3 2.70 68.6 0.075 1.91 2.86 72.7 2164 3626 4807 7158 17477.536000* 3 250 0.52 1.04 26.4 1.14 28.8 3 2.81 71.5 0.075 1.91 2.98 75.6 2528 4184 5307 7902 17477.536200* 3 350 0.62 1.14 29.0 1.23 31.2 2 3.02 76.7 0.075 1.91 3.18 80.8 3514 5675 6595 9820 17477.536500* 3 500 0.74 1.26 32.0 1.35 34.3 1 3.28 83.3 0.085 2.16 3.46 88.0 4983 7887 8485 12634 17477.537000* 3 750 0.91 1.44 36.6 1.54 39.0 1/0 3.67 93.2 0.085 2.16 3.85 97.9 7758 11552 11491 17110 17477.517500* 3 1000 1.06 1.59 40.4 1.69 42.8 1/0 4.00 101.5 0.085 2.16 4.18 106.2 10132 15087 14303 21297 Dimensions and weights are nominal; subject to industry tolerances. *Non-stock item; minimum runs apply. Please consult Customer Service for price and delivery.