Prysmian Mining Cables 11 Anaconda® Type SHD-GC Shielded Round w/Ground-Check 5000 Volts, 90˚C, Three Conductor PRODUCT CONSTRUCTION Conductor: • 6 AWG thru 500 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172 Extruded Strand Shield (ESS): • Extruded thermosetting semi-conducting stress control layer over conductor Insulation: • Ethylene Propylene Rubber (EPR) insulation Insulation Shield: • A flexible coated copper/textile braid shield is applied over a non-conducting overlapped tape using colored textile braid in black, blue, and red for each phase conductor Ground-Check Conductor: • Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene Grounding Conductors: • Coated copper, rope-lay-stranded per ASTM B172 • Two conductors in contact with the flexible copper braid shield Jacket: • Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE) Jacket Marking: • PRYSMIAN MI ANACONDA(R) [XX] [AWG/ KCMIL] 3/C TYPE SHD-GC 5000 VOLTS (-50C) FT1 FT5 SR CSA LR 27161 P-7K- 102046-1 MSHA Options: • Colored jackets • TPU (Thermoplastic Polyurethane) jacket • Neoprene jacket APPLICATIONS: • Designed for use as a trailing cable on AC mining equipment: - Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming) - For high-voltage distribution in underground mines where frequent relocation is necessary FEATURES: • Simultaneous extrusion and vulcanization of both strand shield and insulation form a virtually perfect electrode, eliminating unequal electrical stresses • Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance • Flexible for easy handling • High dielectric strength • Electrical stability under stress • Low dielectric loss • Resists cutting, impact, abrasion, flame and sunlight • Excellent thermal stability and physical properties over a broad temperature range • Two-layer jacket is reinforced to provide maximum protection from mechanical damage—the cause of most portable cable failures COMPLIANCES: • ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications • CSA C22.2 No. 96 Portable Power Cables • Meets flame test requirements and is accepted for listing by MSHA • Approved by the Pennsylvania Department of Environmental Protection PACKAGING: • Material cut to length and shipped on non-returnable reels 6 AWG THRU 500 KCMIL CONDUCTORS, THREE CONDUCTOR, SHIELDED ROUND PORTABLE W/GROUND-CHECK, TYPE SHD-GC - 5000 VOLTS* Catalog number No. of cond. Cond. size (awg/ kcmil) Cond. strand Nominal insulation thickness Grd. cond. size (awg) Grd-check cond. size (awg) Nominal jacket thickness Nominal cable 0.D. Copper weight Net weight Ampacity lbs/ 1000 ft kg/ km lbs/ 1000 ft kg/ km inches mm inches mm inches mm 16241.210600 3 6 133 0.110 2.8 10 8 0.185 4.7 1.58 40.1 540 804 1525 2270 93 16204.858221 3 4 259 0.110 2.8 8 8 0.185 4.7 1.63 41.4 720 1072 1840 2740 122 16202.317964 3 2 259 0.110 2.8 6 8 0.205 5.2 1.86 47.2 1030 1533 2300 3425 159 16201.396409 3 1 259 0.110 2.8 5 8 0.205 5.2 1.95 49.5 1248 1857 2800 4167 184 16241.615100 3 1/0 259 0.110 2.8 4 8 0.220 5.6 2.06 52.3 1533 2281 3045 4530 211 16252.271926 3 2/0 329 0.110 2.8 3 8 0.220 5.6 2.17 55.1 1854 2760 3570 5315 243 16241.215300 3 3/0 413 0.110 2.8 2 8 0.235 6.0 2.53 64.3 2322 3456 4475 6660 279 16254.730315 3 4/0 532 0.110 2.8 1 8 0.235 6.0 2.71 68.8 2936 4369 4960 7380 321 16241.216000 3 250 608 0.120 3.0 1/0 6 0.250 6.4 2.71 68.8 3340 4970 5660 8425 355 16241.216300 3 300 741 0.120 3.0 1/0 6 0.250 6.4 2.81 71.4 3962 5897 6875 10231 398 16262.687414 3 350 851 0.120 3.0 2/0 6 0.265 6.7 2.94 74.7 4522 6730 7150 10640 435 16265.570479 3 500 1221 0.120 3.0 4/0 6 0.280 7.1 3.29 83.6 6515 9696 9625 14325 536 Stock items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/-5%. Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may vary. These ampacities are based on a conductor temperature of 90°C and an ambient air temperature of 40°C, per ICEA S-75-381, NEMA WC58. For ampacities per National Electrical Code® requirements, refer to the latest NEC edition. *100% insulation level, grounded.