Prysmian Mining Cables 16 Anaconda® Type SHD-GC EPR/CPE, Shielded Round w/Ground-Check 35000 Volts, 90˚C, Three Conductor PRODUCT CONSTRUCTION Conductor: • 1 AWG thru 350 kcmil coated annealed copper, bunched wires, rope-lay-stranded per ASTM B172 Extruded Strand Shield (ESS): • Extruded thermosetting semi-conducting stress control layer over conductor Insulation: • Ethylene Propylene Rubber (EPR) insulation colored for contrast with black conducting layers Insulation Shield: • A flexible coated copper/textile braid shield is applied over a semi-conductive extruded insulation shield and a semi-conducting overlapping tape using colored textile braid in black, blue, and red for each phase conductor Ground-Check Conductor: • Annealed copper, rope-lay-stranded per ASTM B172, insulated with high-strength yellow polypropylene Grounding Conductors: • Coated copper, rope-lay-stranded per ASTM B172 • Two conductors in contact with the flexible copper braid shield Jacket: • Reinforced, two-layer, extra-heavy-duty, lead-cured Chlorinated Polyethylene (CPE) Jacket Marking: • PRYSMIAN MI ANACONDA(R) [XX] [AWG/ KCMIL] 3/C TYPE SHD-GC 35000 VOLTS (-50C) FT1 FT5 SR CSA LR 27161 P-7K- 102046-1 MSHA Options: • Colored jackets • TPU (Thermoplastic Polyurethane) jacket • Neoprene jacket APPLICATIONS: • Designed for use as a trailing cable on AC mining equipment: - Where service conditions are severe and maximum safety is mandatory (such as power shovels and draglines in open-pit mines, quarries, gantry cranes and slag reclaiming) - For high-voltage distribution in underground mines where frequent relocation is necessary FEATURES: • Simultaneous extrusion and vulcanization of the strand shield, insulation and insulation shield form a virtually perfect electrode, eliminating unequal electrical stresses • Excellent heat, moisture, steam, oil, corona, chemical and radiation resistance • Flexible for easy handling • High dielectric strength • Electrical stability under stress • Low dielectric loss • Resists cutting, impact, abrasion, flame and sunlight • Excellent thermal stability and physical properties over a broad temperature range • Two-layer jacket is reinforced to provide maximum protection from mechanical damage—the cause of most portable cable failures COMPLIANCES: • ICEA S-75-381 Portable and Power Feeder Cables for use in mines and similar applications • CSA C22.2 No. 96 Portable Power Cables • Meets flame test requirements and is accepted for listing by MSHA • Approved by the Pennsylvania Department of Environmental Protection PACKAGING: • Material cut to length and shipped on non-returnable reels 1 AWG THRU 500 KCMIL CONDUCTORS, THREE CONDUCTOR, SHIELDED ROUND PORTABLE W/GROUND-CHECK, TYPE SHD-GC - 35000 VOLTS* Catalog number No. of cond. Cond. size (awg/ kcmil) Cond. strand Nominal insulation thickness Grd. cond. size (awg) Grd-check cond. size (awg) Nominal jacket thickness Nominal cable 0.D. Copper weight Net weight Ampacity lbs/ 1000 ft kg/ km lbs/ 1000 ft kg/ km inches mm inches mm inches mm 0.380 3 1 259 0.380 9.65 5 8 0.280 7.11 3.29 83.55 1164 1732 4934 7343 191 0.380 3 1/0 259 0.380 9.65 4 8 0.280 7.11 3.40 86.34 1411 2100 5391 8023 218 0.380 3 2/0 329 0.380 9.65 3 8 0.295 7.49 3.52 89.49 1751 2605 6052 9006 249 0.380 3 3/0 413 0.380 9.65 2 8 0.295 7.49 3.68 93.59 2219 3303 6830 10164 286 0.380 3 4/0 532 0.380 9.65 1 8 0.295 7.49 3.79 96.37 2680 3989 7573 11270 327 0.380 3 250 608 0.380 9.65 1/0 6 0.295 7.49 3.94 100.19 3201 4763 8408 12512 360 Stock items are available in long lengths for cutting to your specifications. All lengths are subject to a tolerance of +/-5%. Dimensions and weights shown are nominal, subject to standard industry tolerances. Actual shipping weight may vary. These ampacities are based on a conductor temperature of 90°C and an ambient air temperature of 40°C, per ICEA S-75-381, NEMA WC58. For ampacities per National Electrical Code® requirements, refer to the latest NEC edition. *100% insulation level, grounded.